EB 8048-2 EN
9-3
Servicing
Risk of the process medium being contami-
nated through the use of unsuitable lubri-
cants and/or contaminated tools and com-
ponents.
Î
Keep the valve and the tools used free
from solvents and grease.
Î
Make sure that only suitable lubricants
are used.
The control valve was checked by SAMSON
before delivery.
− Certain test results certified by SAMSON
lose their validity when the valve is
opened. Such testing includes seat leakage
and leak tests.
−
The product warranty becomes void if ser-
vice or repair work not described in these
instructions is performed without prior
agreement by SAMSON's After-sales Ser
-
vice.
− Only use original spare parts by SAM
-
SON, which comply with the original spec
-
ifications.
9.1 Periodic testing
Depending on the operating conditions,
check the valve at certain intervals to prevent
possible failure before it can occur. Plant op-
erators are responsible for drawing up an
inspection and test plan.
Our after-sales service can support you in
drawing up an inspection and test plan for
your plant.
9.2 Checking the extent of
servicing
Î
Check wear at seat and plug. Replace
the damaged plug (see section 9.5.2 or
9.6.2).
Î
Check the diaphragm for damage (e.g.
cracks, milky coloring at the bends). Re-
place the damaged diaphragm (see sec-
tion 9.5.2 or 9.6.2).
Î
If the valve leaks even if the diaphragm
is intact, check the tightening torque of
the joint between plug and plug stem as
well as body and bonnet/flange.
NOTICE
!
Note
Tip
Summary of Contents for 3349
Page 6: ...6 EB 8048 2 EN...
Page 15: ...EB 8048 2 EN 1 9 Safety instructions and measures...
Page 16: ...1 10 EB 8048 2 EN...
Page 34: ...4 6 EB 8048 2 EN...
Page 44: ...5 10 EB 8048 2 EN Installation...
Page 52: ...8 4 EB 8048 2 EN...
Page 66: ...9 14 EB 8048 2 EN...
Page 72: ...12 2 EB 8048 2 EN...
Page 74: ...13 2 EB 8048 2 EN...
Page 92: ...14 18 EB 8048 2 EN...
Page 100: ...15 8 EB 8048 2 EN...
Page 101: ......
Page 102: ......
Page 103: ......