Detailed conditions and results of migration test on PTFE membrane
Overall migration (OM)
The maximum limit on the overall migration (OML) has been tested and measured in accordance with the following
table:
Simulant
Duration
Temperature
Ratio surface /
volume (dm
2
/dl)
OML
(mg/dm
2
)
Results
(mg/dm
2
)
10% ethanol
2 h
Back flow temperature
1
10
1.9
4% acetic acid
2 h
Back flow temperature
1
10
1.8
Vegetal oil
2 h
Back flow temperature
1
10
0.2
Specific migration (SM)
The maximum limits on the specific migration (SML) of substances authorized by the Regulation GB 4806.6
5
and GB
4806.9
5
have been tested and measured in accordance with the following tables:
Polymer name
No
CAS No
SML
(mg/kg)
Status
PTFE= Polytetrafluoro- Ethylène
87
9002-84-0
0.05
OK
Simulant
Duration
Temperature
Item
Results
(mg/kg)
SML
(mg/kg)
Status
4% acetic
acid
2h
Back flow
temperature
As
<0.01
< 0.04
OK
Cd
<0.002
< 0.02
OK
Cr
0.01
< 2.0
OK
Ni
0.02
< 0.5
OK
Pb
0.01
< 0.05
OK
Detailed conditions and results of migration test on metallic parts in steel 1.4435 / 316 L
Overall migration (OM)
The maximum limit on the overall migration (OML) has been tested and measured in accordance with the following
table:
Simulant
Duration
Temperature
Ratio Surface /
volume (dm
2
/dl)
OML
(mg/dm
2
)
Results
(mg/dm
2
)
10% ethanol
2h
Back flow temperature
1
10
1.0
4% acetic acid
2h
Back flow temperature
1
10
1.2
95% ethanol
3.5h
*60°
1
10
0.5
Isooctane
1.5h
*60°
1
10
0.4
*The OL 95% and ISO test conditions correspond to conventional fatty medium substitution test conditions (2 h at 100°C). These
conditions are quoted in the European standard ISO 1186-1 (2002)
Specific migration (SM)
The maximum limit on the specific migration (SML) of substances authorized by the Regulation
GB 4806.9
5
has been
tested and measured in accordance with the following table:
Simulant
Duration
Temperature
Item
Results
(mg/kg)
SML
(mg/kg)
Status
4% acetic acid
2h
Back flow
temperature
As
<0.01
< 0.04
OK
Cd
<0.002
< 0.02
OK
Cr
0.01
< 2.0
OK
Ni
0.02
< 0.5
OK
Pb
0.01
< 0.05
OK
SAMSON REGULATION S.A.S.
SAMSON REGULATION S.A.S.
Bruno Soulas
Head of Strategy and Development
Joséphine Signoles-Fontaine
Head of QSE Department
Summary of Contents for 3349
Page 6: ...6 EB 8048 2 EN...
Page 15: ...EB 8048 2 EN 1 9 Safety instructions and measures...
Page 16: ...1 10 EB 8048 2 EN...
Page 34: ...4 6 EB 8048 2 EN...
Page 44: ...5 10 EB 8048 2 EN Installation...
Page 52: ...8 4 EB 8048 2 EN...
Page 66: ...9 14 EB 8048 2 EN...
Page 72: ...12 2 EB 8048 2 EN...
Page 74: ...13 2 EB 8048 2 EN...
Page 92: ...14 18 EB 8048 2 EN...
Page 100: ...15 8 EB 8048 2 EN...
Page 101: ......
Page 102: ......
Page 103: ......