![Samson 3349 Mounting And Operating Instructions Download Page 48](http://html1.mh-extra.com/html/samson/3349/3349_mounting-and-operating-instructions_3821587048.webp)
7-2
EB 8048-2 EN
Operation
Risk of personal injury due to process me-
dium escaping.
Î
Align the pipe elbow to ensure that any
escaping process medium does not hit
operating personnel.
Î
Wear protective clothing (eye protection,
safety gloves) when working in close
proximity to the control valve.
Diaphragm damage through the use of an
incompressible medium.
Closing the valve when the shut-off valves
upstream and downstream of the valve are
closed may lead to the diaphragm rupturing
in plants with liquid media flowing through
them.
Î
Only close the valve when the shut-off
valves upstream and downstream of the
valve are open.
7.1
Normal operation
The handwheel of valves with actuators fitted
with a handwheel must be in the neutral po-
sition during normal operation.
7.2
Manual operation
Valves with actuators fitted with a handwheel
can be manually closed or opened in the
event of failure of the auxiliary energy sup-
ply.
7.3 CIP (cleaning-in-place)
CIP can be performed with commonly used
cleaning fluids.
Î
Observe the applicable hygiene regula-
tions.
7.4
SIP (sterilization-in-place)
SIP can be performed using steam at a tem-
perature up to 180 °C for a maximum of
30 minutes.
Î
Observe the applicable hygiene regula-
tions.
WARNING
!
NOTICE
!
Summary of Contents for 3349
Page 6: ...6 EB 8048 2 EN...
Page 15: ...EB 8048 2 EN 1 9 Safety instructions and measures...
Page 16: ...1 10 EB 8048 2 EN...
Page 34: ...4 6 EB 8048 2 EN...
Page 44: ...5 10 EB 8048 2 EN Installation...
Page 52: ...8 4 EB 8048 2 EN...
Page 66: ...9 14 EB 8048 2 EN...
Page 72: ...12 2 EB 8048 2 EN...
Page 74: ...13 2 EB 8048 2 EN...
Page 92: ...14 18 EB 8048 2 EN...
Page 100: ...15 8 EB 8048 2 EN...
Page 101: ......
Page 102: ......
Page 103: ......