8
Section 3 |
Layout and Dimensions
3.1.2 SSW-1000-12A, SSW-1500-12A and SSW-2000-12A
1(b)
2
3
9(b)
6
5
1(a)
9(a)
11
10
4
8
9(a)
9
7
Fig 3.2.1 Front of the unit
Fig 3.2.2 Back of the unit
Legend for Fig 3.2.1 and 3.2.2
1(a). AC outlets: NeMA5-20r Duplex GfCI receptacles
1(b). Green indicator light on the GfCI receptacles. Will be oN when normal. Will be off when tripped
2.
oN/off Switch
3.
8P8C Modular Jack (Also called rJ-45 Jack) for connecting remote Control Model SSW-r1-12b
4.
Yellow LeD: Will be oN during (i) over temperature shutdown (ii) Alarm due to Low DC input
voltage (iii) Shut down due to low DC input voltage and (iv) Shut down due to high DC input
voltage
5.
Green LeD: Will be oN when DC Section is operating normally
6.
red LeD: Will be oN during (i) Shut down due to overload and (ii) Shut down due to Ground fault
in the load.
7.
Positive DC Input Connector: Stud and Nut – Size M9
8. Negative DC Input Connector: Stud and Nut – Size M9
9.
Cooling fan [behind the fan grille 9(a)]
9(a). Ventilation grille for fan (Air from fans (9) is discharged outwards)
9(b). Ventilation slots for air inlet for the cooling fans (9)
10. Plastic covers with Thumb Nuts for protecting DC input terminals – red for Positive and black for
Negative
11. earth Ground symbol. The metal chassis of the inverter is internally bonded to the Negative DC
input terminal (8). Connect the Negative DC input terminal (8) on the inverter or the battery
Negative post on the battery to earth Ground
Summary of Contents for SSW-1000-12A
Page 25: ...NOTES ...