5.5.4 Adjusting automatic depth control sensors after repair/installation
The automatic depth control sensors will require readjustment only when disassembled for
maintenance/repair.
•
Lift the machine until the wheels clear the ground.
•
Turn the set screw of the probe about 4 cm into the probe arm.
•
Tighten the lock nut.
•
Move the probe down until the set screw is resting against the stop.
•
Place the reaction arm with the stepped reaction plate just below the bottom sensors and secure with
the locking bolts.
•
Install the spring and test the automatic depth control.
Probe set screw adjustment
Position of reaction arm with plate
relative to the sensors.
NOTE!!!
The sensors and plugs of the magnet coils are provided with a LED to facilitate in controlling their
operation. When in operation, the LED will light up.
NOTE!!!
The minimum distance between sensor and reaction plate is 1.5 mm in order to ensure maximum