DELETE A PROGRAM (C1, C2, C3,…)
- Unplug the machine and wait
20 seconds
before reconnecting.
- Plug in the machine , and within
3 seconds,
press and hold the PRESS
button (15), which accesses the parameters menu.
- Use the UP keys (11) until the
PROGRAMMES
parameter is reached,
then press the
START
button (14) to access the creation or modification
of a programme.
- Use the UP (11) or DOWN (12) keys to locate the programme you want
to delete (C1, C2, C3...).
- Once the programme is located, press the START button (14).
- Once you have accessed the programme configuration:
• The screen shows us, in the upper left, the name of the program (C1,
C2, C3…) and the
phase
(1.2,3..) that you are configuring.
• Enter the stage 1 configuration with the START button (14).
• Find the
End function
using the UP (11) or DOWN (12) buttons and
press START (14). You have successfully deleted the program.
- If you want to exit the machine parameter configuration, push the PRESS
button (15) twice until the
SAMMIC
symbol appears.