SAMLEX AMERICA INC. | 57
Charging voltages of Lithium Ion Battery are not affected by temperature and hence,
Battery Temperature Sensor
Model EVO-BCTS must NOT be used when Lithium Ion batteries are used
. The RJ-45 Jack marked "Battery Temp
Sensor"
[6, Fig 2.1]
can be used to feed control signals from certain Lithium Ion Battery Management Systems (
BMS
)
that may have capability of enabling / disabling
“Stop Charging”
or
“Stop Inverting”
control signals for inverter
chargers. This control signal is normally generated by the BMS by switching ON (
enabling
) or switching OFF (
disabling
)
potential free, Drain (+) and Source (-) terminals of mini Opto Isolated Mosfet Switch
[Solid-State Relay (SSR)]
.
Connect the control signal output from the BMS to RJ-45 Jack marked "Battery Temp Sensor"
[6, Fig 2.1]
as follows:
•
BMS control signal terminal marked “+”:
o Connect to any of Pins 1/2/3/4 [
Refer to Fig 3.12 for pinout of RJ-45 Jack. Pins 1 to 4 are internally shorted]
•
BMS control signal terminal marked “-”:
o Connect to any of Pins 5/6/7/8
[Refer to Fig 3.12 for pinout of RJ-45 Jack. Pins 5 to 8 internally shorted]
3.17 SHORE BASED INSTALLATION
Fig. 3.13 illustrates a typical shore based installation.
• Battery is connected to the DC input connections through DC Electrical Panel with an appropriate fuse to
protect the DC input cables against short circuit
• Battery Charger Temperature Sensor Model EVO-BCTS is installed on the Positive or Negative post of the
battery and connected to the RJ-45 Jack for the Temperature Sensor
• Supplementary battery charging is being carried out through a solar array and a Charge Controller connected
to the DC input provided for external charge controller.
• AC input to the EVO™ is fed from the Grid. Alternatively, AC input may be fed from a generator.
• AC output from the EVO™ is fed to the AC Electrical Sub-Panel
WARNING!
In case generator is used to feed AC input to the EVO™, the following should be ensured:
• Ensure that the Neutral of the generator is bonded to the chassis of the generator and the chassis of the
generator is bonded to Earth Ground through Ground Rod. Please see Section 3.14.1 for details.
MISE EN GARDE!
En cas générateur est utilisé pour l'alimentation d'entrée AC à l'EVO
™
, les dispositions suivantes
devraient être prises :
• S'assurer que le neutre du générateur est fixé sur le châssis du générateur et que le châssis du générateur
est relié à la terre via la tige de mise à la terre. Veuillez voir la section 3.14.1 pour plus de détails.