18 | SAMLEX AMERICA INC.
APPENDIX A
SECTION 4 |
Parameter Setup
COMPENSATE:
This parameter sets the temperature compensation for the battery. The operational range of
the EVO Inverter Charger is -20°C to 60°C.
This compensation voltage will affect the Absorbtion Voltage/Equalize Voltage/Floating Voltage/
Batt Over Volt/Restart Voltage/Low Volt Alarm/Batt Low Voltage when the Temperature Sensor
is installed on the battery (see Fig 2.5 in the Owner's Manual for EVO Inverter Charger).
SELECT GROUP
CHARGE CURVE
BULK CURRENT
40 A
COMPENSATE
4
Enter Key
ò
Up Key x 4
ò
mV/C/C
BATT OVER VOLT:
This parameter sets the upper battery voltage threshold at which inverting / charging opera-
tions are switched OFF to protect the unit against damage due to battery overvoltage:
•
AC input is not available and EVO Inverter Charger is operating in Inverting Mode:
When the battery voltage rises to the set upper threshold of “BATT OVER VOLT”, the In-
verter Section will be shut down and message “Battery over voltage!” will be displayed on
the LCD screen. The Green LED marked “Status” will switch OFF and the Red LED marked
“Alarm” will remain ON steady. The buzzer on EVO Inverter Charger will beep steady. The
fault will be cleared automatically when the battery voltage drops to 0.5V below the set
upper threshold of “BATT OVER VOLT”
•
AC input is available and EVO Inverter Charger is operating in Charging Mode:
When the battery voltage rises to the set upper threshold of “BATT OVER VOLT”, the Trans-
fer Relay will be de-energized, charging and pass through will be stopped and PWM drive to
the Inverter Section will be switched OFF. Message “Battery over voltage!” will be displayed
on the LCD screen. The Green LED marked “Status” will switch OFF and the Red LED marked
“Alarm” will remain ON steady. The Buzzer on EVO Inverter Charger will beep steady. The
fault will be cleared automatically when the battery voltage drops to 0.5V below to the set
upper threshold of “BATT OVER VOLT”. The unit will start in Inverting Mode, synchronize
with the AC input and then, the Transfer Relay will be energized to transfer to AC input at
zero crossing. The unit will, thus, resume operation in “Charging Mode”.
SELECT GROUP
CHARGE CURVE
BULK CURRENT
40 A
BATT OVER VOLT
16.00 V
Enter Key
ò
Up Key x 5
ò
RESET VOLTAGE:
The inverter will restart when the battery voltage rises above this set value after Battery Low
Voltage shutdown occurs. If Relay Function is set for Generator, the relay will turn OFF.
SELECT GROUP
CHARGE CURVE
BULK CURRENT
40 A
RESET VOLTAGE
12.50 V
Enter Key
ò
Up Key x 6
ò