Fault causes/troubleshooting
Potential faults
Possible consequences
Troubleshooting
The jar lid is screwed onto
the jar at an angle.
The mixing blade tilts upon automa-
tic entry into the bayonet mount.
Screw the lid onto the jar properly
and tightly.
The oscillation arm is
pulled too far from the
defined starting position
by hand.
The mixing blade shaft is not cente-
red in the holder after performing a
full stroke.
Take hold of the mixing blade shaft
at the taper and manually guide it
into the holder.
The mixing unit is not
held firmly with at least
one hand during the en-
tire mixing period in the
case of a manual lifting
process.
Risk of injury as a result of unstable
holding of the mixing unit during the
entire mixing process in the case of
manual lifting process.
Firmly hold the mixing unit with at
least one hand during the entire
mixing period in the case of manual
lifting process.
After heavy loads, the de-
vice is not switched off for
cooling.
In the event of an overload, a ther-
mal safety element shuts down the
mixing function of the device.
Switch off the power switch or dis-
connect the connector. Switch off
the device and allow to cool for 30
minutes.
No air reduction is perfor-
med before handover of
the jar to the operator.
The air reduction serves for pushing
out any air-filled spaces arising du
-
ring the mixing process. During the
first withdrawal the operator first pu
-
shes the air and then the ointment
from the jar opening in a gushing
movement.
Perform air reduction before the
handover of the jar to the operator.
If necessary, use a vario nozzle or
an applicator.
Tab. 7: Possible fault sources to avoid