SAMES KREMLIN
- 2 -
N° : 578.122.110-UK-1802
OPERATION TO CARRY OUT
FREQUENCY
D
W
M
Q
H
Y
FLUID SECTION
Check the tightness of the cup
X
Check if there is lubricant in the cupel
(keep the level halfway up)
X
Disassemble the fluid section, clean the parts with the
appropriate cleaning solvent, change the seals and
the parts if necessary
X
Change the lubricant if the coloration is too important
and change the seals of the upper flange if the
problem persists
X
Clean regularly the cup with lubricant after having
drained the lubricant
X
D : daily
W : weekly
M : monthly
Q : quarterly
H : half-yearly
Y : yearly
Note : Frequencies are given as a clue. They must be adapted by the maintenance
service of the user for every installation according to the product, the working cadence
and the working pressure.