Doc.-ID: 181210-PT10BA-ES-RoughCam IPM3016_en_rev.00.docx, page 4 of 24
1
Introduction
The RoughCam IPM3016 is a very compact and robust digital camera (type T10) which is
manufactured by SAMCON Prozessleittechnik GmbH and can be used very flexibly for
various applications. Due to its dimensions and adaption options as well as the exchange-
able lenses with various angle of views, focal length and areas of focus, even sight glass
applications and process observations with only little object distances are possible.
Besides for fixed installation, the RoughCam IPM3016 is also certified to be used for mo-
bile applications (hand-held).
Due to the usage of high-quality PTFE sealings, not only the protection level IP68 is met
but also the chemical resistance is maximized.
2
Technical Data
2.1
Illustration of the model key
Modelvariants
Options
Productname
1)
Type
2)
Housing
combination
3)
Temperature
range
4)
Cable length/m
5)
Cable
termin.
6)
Lens
7)
RoughCam
IPM3016
T10-
VA1.2.K1.BOR-
N.N-
005.N-
P-
090/046/017
T10-
VA1.2.K1.BOR-
N.N-
005.N-
T-
090/046/017
T10-
VA1.2.K1.BOR-
LL.N-
005.N-
T-
090/046/017
Table 2.1
– Model key
Explanations:
1)
RoughCam IP
M3016 =
Functional camera description of the RoughCam (technical data /
specification of the individual camera module)
2)
T
10
=
SAMCON Production type 10 (for safe areas)
3)
VA1
.2.K1.BOR =
T11 housing (stainless steel 1.4404) with small diameter (Ø
VA
=79mm)
VA1.
2
.K1.BOR =
T11 VA1.x housing with maximum body length (L
VA1.2.R
= 136mm)
VA1.2.
K1
.BOR =
K1 cable gland flange (axial cable gland, standard)
VA1.2.K1.
BOR
=
Borosilicate sight glass DIN7080 standard execution, for video cameras
within visible spectral range and photographical infrared range (NIR), not
suitable for thermographic applications (MIR/ FIR)
4)
N.
N
=
Normal ambient temperature range, no heater installed (T
amb
> -5°C)
N.
N
=
No cooling system installed (T
amb
< +55°C)
LL
.N=
PTC heater installed (T
amb
> -60°C)
5)
005
.N =
Length of the connection line in meter at delivery. The standard cable
length is 5 m, minimum/ maximum cable length is: 001
…095 [m] for