Doc.-ID: 181210-PT10BA-ES-RoughCam IPM3016_en_rev.00.docx, page 15 of 24
For model key
„LL“ (
RoughCam with PTC heating
) the wires of the system cables are,
for marshalling the PoE transmission and heating supply, assigned as follows:
Camera side / Internal Wiring
System Cable
Junction
Box
Pin/ Potential
100BaseTx/PoE
Color
(IEC60757)
Plug
contact
(TIA-
568B)
Profile
AWG24/7
Terminal
Comments
Area
[mm
2
]
Diameter
[mm]
Mode A
Mode B
-
-.
PE
(enclosure)
SHD.
-
-
PE
SHD
Tx+ /
PoE ±48 VDC
Tx+
WH / OG
1
0.23
0.61
1
Tx- /
PoE ±48 VDC
Tx-
OG
2
023
0.61
2
Rx+ /
PoE GND
Rx+
WH / GN
3
0.23
0.61
3
Rx- /
PoE GND
Rx-
GN
6
0.23
0.61
4
n.c.
n.c.
n.c.
n.c.
5
n.c.
n.c.
n.c.
n.c.
6
n.c.
n.c.
n.c.
n.c.
7
n.c.
n.c.
n.c.
n.c.
8
Shield A/ GND
(twisted pair)
-
GND
(Plug)
FOIL.
-
PE.
PE
L+ /
+24 VDC
n.a.
WH / BN
BN
-
2 x
0.23
2 x
0.61
9
L+ (Heater)
L- /
GND
n.a.
WH / BU
BU
-
2 x
0.23
2x
0.61
10
L- (Heater)
PE
Table 4.3
– Electrical connection for model key “LL.N“
The maximum cable length for models with heater is 5m from the camera to the Ex-e ter-
minal box.
Attention!
Perform the foiling up to about 10mm to the terminals, in order to pre-
vent alien over speak. Make sure that the foiling cannot cause any short
circuit of the data couples!
Attention!
Bring the twisted pair composite approximately 10mm close to the ter-
minals, in order to ensure the immunity to disturbance.
Attention!
Use only terminals approved by SAMCON.