Attention
:
Via a „heavy duty“ RJ45 network plug, the hardware is connected to the system
cable. For low temperature models, there are also two further wires (BK) and an additional
plug connection (WH) to the heating module. It is not mandatory to unplug the RJ45 plug
but it might facilitate the handling. If the cable is unplugged, please make sure to re-loop it
later on.
Carefully tilt the mounting adapter so that through the opening, the right push button can
be pressed to carry out the hardware reset (q.v. Figure 5.2).
Please make sure not to damage any electrical installations, cable interfaces, the lens, or
the mounting components. Also, please do not to exert mechanical strain on the aforemen-
tioned components. Please be aware that the measures run a risk of distorting the optical
axis which leads to a reduction in the picture quality!
When touching electrical components, potential equalization (ground-
ing of the body) has to be observed (ESD clothing, PE wristband etc.)!
For carrying out the hardware reset, please refer to the Axis user manual (page 15) which
describes the individual steps:
https://www.axis.com/files/manuals/um_m30_1741648_en_1709.pdf
After the successful hardware reset, the mounting adapter has to be fixed again with the
three M3*0.5 original screws and the associated washers. A tightening torque of 2.5 Nm
is recommended!
When closing the housing, the cable routing has to be observed! In order to avoid colli-
sions and mechanical strain within the closed housing as well as to observe the neces-
sary bending radius, the cable has to be looped.
5.3
Closing of the housing
ATTENTION!
Do not lock-in any foreign objects in the housing
Cylinder head scrrews always have to be tightened evenly and
crosswise with a tightening torque of 3.0 Nm