Doc.-ID: 181210-PT10BA-ES-RoughCam IPM3016_en_rev.00.docx, page 14 of 24
For model key
„N“ (RoughCam
without PTC heating
) the pin assignment
is in accord-
ance with the standard EIA/TIA-568B for 100BaseTX with PoE
(IEEE 802.3af/at):
Camera side / Internal Wiring
System Cable
Junction
Box
Pin/ Potential
100BaseTx/PoE
Color
(IEC60757)
Plug
contact
(TIA-
568B)
Profile
AWG24/7
Terminal
Comments
Area
[mm
2
]
Diameter
[mm]
Mode A
Mode B
-
-.
PE
(enclosure)
SHD.
-
-
PE
SHD
Tx+ /
PoE ±48 VDC
Tx+
WH / OG
1
0.23
0.61
1
Tx- /
PoE ±48 VDC
Tx-
OG
2
023
0.61
2
Rx+ /
PoE GND
Rx+
WH / GN
3
0.23
0.61
3
Rx- /
PoE GND
Rx-
GN
6
0.23
0.61
4
n.a.
PoE
+48 VDC
WH / BU
5
0.23
0.61
5
n.a.
PoE
+48 VDC
BU
4
0.23
0.61
6
n.a
.
PoE
GND
WH / BN
7
0.23
0.61
7
n.a.
PoE
GND
BN
8
0.23
0.61
8
Shield A/ GND
(twisted pair)
-
GND
(Plug)
-.
-
PE.
PE
n.c.
n.c.
n.c.
n.c.
n.c.
n.c.
9
n.c.
n.c.
n.c.
n.c.
n.c.
n.c.
10
-.
-
-
PE
Table 4.2
– Electrical connection for model key „N.N“
Particularly in EMC critical environments, it is necessary to make sure that the cable shield is
grounded on side of the terminal block
(wire and pin contact No. 9, q.v. figure 4.6). The
maximum cable length between camera and junction box for models without heating is