Doc.-ID: 190314-PT08BA-ES-ExCam XF-P1367_EN_rev.00.docx, Page 12 of 32
In accordance with standard EIA/TIA-568B for 100BaseTX and 24 V DC for terminal
boxes, we recommend the following core wire assignment for the SKDP03-T cable:
Camera (Ex-d)
(T568B)
Colour
SKDP03-T
(IEC60757)
Terminal
ExTB-3
Cross-
sectional
surface
Comment
Tx+
WH / OG
1
0.25 mm
2
Solid conductor
Tx-
OG
2
0.25 mm
2
Solid conductor
Rx+
WH / GN
3
0.25 mm
2
Solid conductor
Rx-
GN
4
0.25 mm
2
Solid conductor
(PoE +48 VDC)
WH / BU
5
0.25 mm
2
Solid conductor
(PoE +48 VDC)
BU
6
0.25 mm
2
Solid conductor
(PoE GND)
WH / BN
7
0.25 mm
2
Solid conductor
(PoE GND)
BN
8
0.25 mm
2
Solid conductor
GND/SHD
YE / GN
PE
2.5 mm
2
Flex
L+
BK
9
1.5 mm
2
L+ 24VDC
L-
BU
10
1.5 mm
2
L- 24VDC
PE
YE / GN
PE
1.5 mm
2
PE
Tab. 5-3. Wire assignment of terminal box ExTB-3
Video Tutorial:
Please view our video tutorial
:
“SAMCON 01 Wiring the cable SKDP03-T to the junction box ExTB-3”
Fig. 5-4 Video Tutorial ExTB-3