Doc.-ID: 190314-PT08BA-ES-ExCam XF-P1367_EN_rev.00.docx, Page 24 of 32
6.4
Status LED
The user can see the Status LED (Fig. 6-4) only if the camera housing is open.
6.5
Hardware Reset
To re-set all parameters of the ExCam XF P1367 (including the IP address) to default
setting, a hardware reset has to be carried out.
The parameters can be either reset via the web interface or manually. If the camera in
the network can no longer be reached or its state is uncontrollable, the reset should be
performed manually. To do so, proceed as follows:
1. Disconnect the camera installation module (Axis P1367) from the power supply.
2. Press and hold the control button 13 (see the illustration 6-4) and, at the same
time, connect the system to the voltage supply (PoE).
3. Press and hold the control button until status indicator 2 (Fig. 6-4) lights yellow
(wait about 30 seconds).
4. Release the control button. When the status indicator lights green (it can take
about 1 minute), P1367 will be reset to the factory settings axis. If there is a DHCP
server in the network, the IP address will be the following: 192.168.0.90 (subnet
masking 255.255.255.0).
5. IP address and password can be redefined. If the hardware reset is not satisfacto-
ry, or the network camera shows serious conflicts, or does not work as usually (er-
rors in the browser visualisation, frozen images, control commands no longer pro-
cessed, slowing down of the system, etc.), it may be necessary to re-install the
current firmware, or to install an update (see Chapter 7).
6.6
Closing of the pressure-resistant housing
For closing the housing, proceed in reverse order as when opening. Use exclusively orig-
inal screws included in the supply.
The cable and power-supply flange (K3) is fixed by 8 cylinder-head screws M4*0.7 (ISO
metric right-turning) with 30 mm thread length (DIN 912/ ISO 4762, grade 6g). Materials
of bolted connections are identical to the pressure-resistant stainless steel housing
(standard material no. 1.4404 AISI316L). Check whether the threaded holes are undam-
aged and clean. Before closing, it is also absolutely imperative to check the flame-proof
gap (circular cylindrical fit).