Doc.-ID: 190314-PT08BA-ES-ExCam XF-P1367_EN_rev.00.docx, Page 14 of 32
Attention!
Introduce the foiling up to about 15 mm to the terminals, in order to pre-
vent alien crosstalk. Make sure that the foiling cannot cause any short
circuit of the data pairs!
Attention!
Bring the twisted pair composite approximately 10mm close to the termi-
nals, in order to ensure the interference immunity.
Attention!
Use only terminals approved by SAMCON.
Attention!
Finally, check your network installation by per Class-D Link Test.
5.3
Example: external connection and fusing via the terminal box
There are several options of routing the ExTB-3 terminal box in a safe area:
5.3.1
Example: direct routing from the ExTB-3 to the safe area
Fig 5-7 ExTB-3 -> Safe area
Switch/
PoE
15W
24 V DC for heating
PoE (802.3at) for camera