Doc.-ID: 190314-PT08BA-ES-ExCam XF-P1367_EN_rev.00.docx, Page 27 of 32
The focus of the ExCam XF P1367 network camera is optimised by the manufacturer to
about 10 m object distance. The complete viewing angle is located in the "wide" area.
This means a horizontal viewing angle of 98°. Usially, no adjustment is required. To focus
the objects at a smaller or greater distance, or to change the zoom range (wide -> tele),
you can change the lens settings, as follows:
1. Via a web browser (Mozilla Firefox, MS Internet Explorer, etc.), open the user in-
terface of ExCam XF P1367 (for network access, see Chapter 8). Navigate in the
"Setup" menu via the "Basic Setup" pull-down menu to the "Focus" settings.
2. Follow the shown instructions and first click on the "Open iris" button. If this button
is disabled, this means that the iris is already open.
3. Now click on "Reset", to reset the lens level to the default value
4. Release the zoom and sharpness regulators on the lens, by turning
it
counter-
clockwise. By moving the two regulators, adjust the zoom strength and image
sharpness. Check the image quality in the window below.
5. Re-tighten the zoom and sharpness regulators.
6. The click on the button "Fine-tune focus automatically" in the configuration menu
and wait until the automatic optimization is finished.
7. To re-enable the iris, click "Enable iris". If the button is disabled, this means that
the iris is already activated.
8. If necessary, you can make further settings in
the "Advanced” tab.
Please note:
Before you start the automatic fine tuning, adjust the image sharpness as precisely as
possible with the aid of the sharpness regulator or focus wizard. The sharpness regulator
usually provides the best results.
8
Network access and visualization
The most important procedures of the camera
’s initial commissioning are described be-
low. The configuration menu of the web surface allows an intuitive navigation and offers
several configuration possibilities. For detailed documentation and information how to
use the web Interface, please see the User Manual for Axis or visit the following website:
https://www.axis.com/products/axis-p1367