Salvislab Thermocenter TC40/100 User Manual
- 8
Copyright© SalvisLab / Edition 30062016_2.0
4
Technical data
[unit]
TC40
TC100
Outer Dimension
Width
mm
460
570
Height
mm
507
620
Depth
mm
525
656
Clearance distance from back wall
mm
100
100
Clearance distance from side wall
mm
100
100
Inner Dimension
Width
mm
340
450
Height
mm
370
500
Depth
mm
328
456
Internal Volume
L
40
100
Shelf
standard/max
1/8
1/8
Shelf dimension (WxD)
mm
295x324
437x425
Distance between shelf
mm
35
50
Max. load per shelf
kg
20
20
Max. load per oven
kg
40
50
Weight oven (empty)
kg
30
50
Temperature range approx. 5°C > T
r
to
°C
200
200
Temperature deviation
1)
at 50°C
± °C
0.4
0.4
Temperature deviation
1)
at 100°C
± °C
1.0
1.0
Temperature deviation
1)
at 150°C
± °C
1.5
1.7
Temperature fluctuation
2)
at 150°C
± °C
0.2
0.2
Heating up time
3)
to 70°C
min
10
15
to 150°C
min
24
35
to 200°C
min
34
45
Recovering time after 30 sec door opening
3)
at 100°C
min
4
7
Air changes (exhaust flap open)
at 100°C
x/h
59
29
Power supply (±10%) 50/60 Hz
Volt
115/230
115/230
Nominal Wattage
Watt
1100
1100
Energy consumption
at 100°C
Watt
145
230
at 150°C
Watt
300
544
Recommended ambient values
T
°C
15 - 25
15 - 25
ϕ
%
20 - 60
20 - 60
Equipment
SalvisTEQ controller with predictive regulation
-
Yes
Yes
Capacitive touch display
inches/pixels
5.7”/640x480
5.7”/640x480
Linear/logarithmic heating gradient
-
Yes
Yes
Adjustable fan speed
%
60 - 100
60 - 100
Multi user levels
-
Yes
Yes
Program mode
programs/steps
99/99
99/99
USB host interface for data import/export
-
Yes
Yes
Ethernet port
-
Yes
Yes
Preselectable restart procedure in case of power failure
-
Yes
Yes
Timer and counter
hours/min
0-999/59
0-999/59
1)
Measured with 3 temperature probes on horizontal level / divided in 1/3 of the chamber size
2)
maximum temperature deviation in time for one temperature probe
3)
to 98% of set temperature
All technical specification are specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a voltage fluctuation of ±10 %. The
temperature data are determinated in accordance to following DIN 12880, part 2 respecting the recommended wall clearances of 10 % of the height, width and
depth of the inner chamber. All indications are average values, typical for units produced in series. Differing ambient temperatures or variances in the design of
individual equipment may produce different performance. We reserve the right to alter technical specifications at all times without prior notice.
*We reserve the right to alter technical specifications at any time without prior notice.