SALVA INDUSTRIAL, S.A
File: Horno Modular 02 (ing) 180711
1-1
1. PREASSEMBLY INSTRUCTIONS
1.1 STORAGE AND TRANSPORT
The oven is sent packed on a wooden platform covered with plastic film, that protects the machine
against humidity and rain. The oven should be transported in a completely closed vehicle, and it
should never be left outdoor.
1.2 CONDITIONS FOR USE
•
The oven has been manufactured to be installed indoor. It is not made to work outdoor. Any
possible contact with water has to be avoided.
•
The oven should not be installed in places with excessive heat, steam and/or humidity production.
•
The oven is prepared to work under the following external conditions: -10 + 40 ºC, and 0 + 90 %
of humidity.
•
The room in which the oven has to be installed must have adequate ventilation. If there is a
fumes extractor, then a window with at least the section of the fumes extractor should be kept
open.
•
The position of the oven regarding the side and back wall of the installation premises should have
a minimum distance of 2" (50 mm) between the oven sides and the walls of the room.
1.3 GENERAL INFORMATION
This type of oven basically is comprised of independent decks of standardized production, who
manufactured from metal and stainless steel.
Assembly of this unit is carried out by piling decks with the same surface, two different levels may
be installed, thus enabling different combinations, according to client's requirements. These
decks are manufactured in two different height sizes with inner chamber measures being 7.9 (200
mm) and 9.8 inches (250 mm).
The oven unit is always supported by the BASE, and the different DECKS are piled on this,
finished with a TOP with a hood for fume removal. At the same time, the base may be supported
by a PROOFER with WHEELS, for fermentations, or in the case or ovens of great height, on four
wheels directly to the base. The heating elements may be interchangeable. The temperature of
each deck is electronically controlled from a CONTROL PANEL, located on the right hand side of
the front part of the deck. The LIGHTING PANEL is located next to this control panel, and the
inside of the chamber is lit from the same, as well as the replacement of the lamp of the same.
The control for the handle which opens and closes fume extraction from the inside of the
chamber, is located on the left hand on the front panel; the fumes go to a general collector
located on the back of the deck.
Summary of Contents for ST-02
Page 2: ......
Page 4: ......
Page 21: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 4 1 4 ELECTRONIC CONTROLPANEL...
Page 35: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 6 3...
Page 39: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 1 9 ELECTRICAL SCHEME...
Page 40: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 2...
Page 41: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 3...
Page 42: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 4...
Page 43: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 5...
Page 44: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 6...
Page 45: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 7...
Page 46: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 8...
Page 47: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 9...
Page 48: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 10...
Page 49: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 11...
Page 50: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 12...
Page 51: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 13...
Page 52: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 14...
Page 53: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 15...
Page 54: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 16...
Page 55: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 17...
Page 56: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 18...
Page 57: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 19...
Page 58: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 20...
Page 59: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 21...
Page 60: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 22...
Page 61: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 23...
Page 62: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 24...
Page 63: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 25...
Page 64: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 26...
Page 65: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 9 27...
Page 73: ...SALVA INDUSTRIAL S A File Horno Modular 02 ing 180711 11 6...