background image

DOMINATOR

PLUS

 

G3151 Fusion Range 
G3150 Fusion Boiling Top 

 

 

INSTALLATION and 
SERVICING INSTRUCTIONS

 

 

This appliance must be installed and serviced by a competent person as stipulated by the 
Gas Safety (Installation & Use) Regulations.

 

 

IMPORTANT

 

The installer must ensure that the installation of the appliance is in conformity with these instructions 
and National Regulations in force at the time of installation. Particular attention MUST be paid to:

 

 

Gas Safety (Installation & Use) Regulations 
Health And Safety At Work etc. Act

 

Local and National Building Regulations 
Fire Precautions Act

 

Detailed recommendations are contained in 
Institute of Gas Engineers published documents: 
IGE/UP1, IGE/UP/2

 

BS6173 and BS5440

 

 

The appliance has been CE-marked on the basis of compliance with the Gas Appliance Directive for 
the Countries, Gas Types and Pressures as stated on the data plate.

 

 

 

WARNING

TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC, 

MUST BE EARTHED.

 

On  completion  of  the  installation,  these  instructions  should  be  left  with  the  Engineer-in-Charge  for 
reference during servicing. Further to this, The Users Instructions should be handed over to the User, 
having had a demonstration of the operation and cleaning of the appliance.

 

 

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING 
AND  COMMISSIONING  THIS  APPLIANCE.  FAILURE  TO  COMPLY  WITH  THE  SPECIFIED 
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

 

 

PREVENTATIVE MAINTENANCE CONTRACT

 

In  order  to  obtain  maximum  performance  from  this  unit  we  would  recommend  that  a  maintenance 
contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out 
adjustments and repairs. A quotation will be given upon request to the contact numbers below.

 

 

WEEE Directive Registration No. WEE/DC0059TT/PRO  
At end of unit life, dispose of appliance and any replacement 
parts in a safe manner, via a licenced waste handler.

 

Units are designed to be dismantled easily and recycling of all 
material is encouraged whenever practicable.

 

 
 
 

 

Falcon Foodservice Equipment

 

HEAD OFFICE AND WORKS

 

Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.

 

SERVICELINE CONTACT

 

Phone: 01438 363 000 

Fax: 01438 369 900

 

T100850 Ref. 2

Summary of Contents for Dominator Plus G3151

Page 1: ...ions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and...

Page 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Page 3: ...VENTILATION Adequate ventilation must be provided to supply sufficient fresh air for combustion and allow easy removal of combustion products which may be harmful to health Recommendations for Ventil...

Page 4: ...rnor BSP is provided on Natural gas units This should be adjusted to achieve an operating pressure at control manifold of 15mbar For muti burner systems approximately half of the burners should be on...

Page 5: ...ner heads fit loosely upon aluminium bases of lift off construction 2 1 1 Fryplate Accessory If fryplate Figure 2 is supplied refer to user instructions for details Important note this should be opera...

Page 6: ...d select 210 C setting Allow oven to heat up and check temperature is 210 C 10 C If reading is outwith specified range the thermostat may be faulty In this case unit should be serviced see thermostat...

Page 7: ...gure 7 a Remove control panel b Unscrew and remove existing low position screw from open top tap c Insert replacement screw into open top tap and secure Repeat for all taps d Refit control panel 3 1 3...

Page 8: ...venturi that sit loosely upon injector holder The hob is retained by ballstud fixings at each corner Lift hob clear to access burner support brackets 3 2 3 To Remove Hob Remove fixings that secure fr...

Page 9: ...ove Thermocouple Remove facia panel as detailed in Section 3 2 1 Remove hob fitments See Sections 3 2 2 or 3 2 3 as required Remove RH side panel Undo thermocouple nut at thermostat rear Open over doo...

Page 10: ...otects the breather hole When checking for gas leaks around governor be aware that unburned gas may be vented occasionally to release pressure on diaphragm This should not be confused with a gas leak...