Work to the product/unit must only be carried out when at a
standstill. It is mandatory that the procedure described in the
installation and operating instructions for shutting down the
product/unit be complied with.

Immediately on conclusion of the work, all safety and protec-
tive devices must be put back in position and/or recommis-
sioned.

2.7 Unauthorised modification and 

manufacture of spare parts

Unauthorised modification and manufacture of spare parts will
put the safety of the product/personnel at risk and invalidate
the statements on safety made by the manufacturer. 

Modifications to the product are only permissible after consul-
tation with the manufacturer. Original spare parts and acces-
sories authorised by the manufacturer ensure safety. The use of
other parts nullifies the liability from the results of the usage.

2.8 Improper use

The operating safety of the supplied product is only guaran-
teed for conventional use in accordance with Section 4 of the
operating instructions. The limit values must on no account fall
under or exceed those specified in the catalogue/data sheet.

3. TRANSPORT AND INTERIM STORAGE

Immediately after receiving the product:

•Check product for transport damage,

•In the event of damage in transit, take the necessary steps with

the forwarding agent within the respective time limits. 

CAUTION! Risk of damage!
Inappropriate transport and interim storage can cause
damage to the product.

•The switchgear is to be protected against moisture and 

mechanical damage. 

•It must not be exposed to temperatures outside the 

range –20 °C to +60 °C.

4. INTENDED USE

The EC-Drain 2x4.0 switchgear is for automatic control of two
pumps with a maximum power consumption of P

 4,0 KW:

•in lifting units,

•for submersible pumps.

DANGER! Risk of fatal injury!
The switchgear is not protected against explosions and
may not be operated in the explosive area.

•Always install the switchgear outside the explosive 

area.

•Use breakdown barriers when using float switches in 

potentially explosive areas.

•In the case of usage in potentially explosive areas, be 

sure to comply with all applicable explosion protection 
regulations.

The intended use includes complying with these instructions.

Any other use is considered outside the intended use.

5. PRODUCT INFORMATION

5.1 Type key

5.3 Scope of delivery

•EC-Drain 2x4.0 switchgear (with built-in buzzer)

•Accessories kit

– 3 x reducer seals for threaded cable connection

•Installation and operating instructions

5.4 Accessories

Accessories must be ordered separately:

•Rechargeable battery (NiMH) 9 V/200 mAh

•Horn 230 V/50 Hz

•Flash light 230 V/50 Hz

•Signal lamp 230 V/50 Hz

See the catalogue for a detailed list

6. DESCRIPTION AND FUNCTION

6.1 Description of the product (Fig. 1)

The EC-Drain 2x4.0 is an electronic switchgear with a built-in
microcontroller.

It controls two pumps depending on the switching status of the
connected float switch. When the high water level is reached,
an optical and acoustic signal are output and there is a forced
pump switch-on. The collective fault signal and high water
alarm are active. 

An optional rechargeable battery (accessory) enables a
mains-independent alarm signal, which indicates the mains
voltage is missing by means of a continuous acoustic signal. 

Pump faults are registered and evaluated. 

The display of the operating statuses is signalled by LEDs on the
front. It is operated by buttons on the right side of the housing.

Example: EC-Drain 

2x4.0

EC

Economy-Controller

Drain

Wastewater/sewage

2x

2=double-pump control

4.0

Max. permissible rated power [kW] of the 
pump

5.2 Technical data

Mains supply voltage 
[V]:

1~230 V (L, N, PE)
3~400 V (L1, L2, L3, PE)

Frequency [Hz]:

50/60 Hz

Control voltage [V]:

24 V DC

Power consumption 
[VA]:

Max. 15 VA (contactor activated)
Max. 8 VA (downtime status)

Max. switching capacity 
[kW]:

P

 4 kW, AC 3

Max. current [A]:

12 A 

Motor protection:

Integrated thermal protection 
(WSK) in the pump motor

Protection class:

IP 54

Max. fuse protection on 
mains side [A]:

25 A, slow-blow 

Ambient temperature 
[°C]:

–20 to +60 °C

Alarm contact:

Contact load max. 250 V~, 1 A

Housing material:

ABS

Housing dimensions:

289 mm x 239 mm x 155 mm 
(WxHxD)

Electrical safety:

Degree of contamination II

Summary of Contents for EC-Drain 2x4,0

Page 1: ...N ET MISE EN SERVICE INSTALLATION AND STARTING INSTRUCTIONS FRAN AIS ENGLISH INSTALLAZIONE E MESSA IN SERVIZIO ITALIANO INSTALACION Y PUESTA EN SERVICIO ESPA OL N M S STOCK N 2 533 857 Ed 02 07 11 EC...

Page 2: ...2...

Page 3: ...3...

Page 4: ...2 3 4 5 6 7 SSM Alarm GL WSK P2 WSK P1 SL 10 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 HW T1 1 3 5 13 A1 2 4 6 14 A2 T2 T3 L1 L2 L3 NO WSK M 3 WSK M 1 1 2 3 4 5 T1 1 3 5 13 A1 2 4 6 14 A2 T2 T3 L1 L2 L3 NO...

Page 5: ...ent tre imp rativement respect es et maintenues dans un tat bien lisible 2 2 Qualification du personnel Il convient de veiller la qualification du personnel amen r aliser le montage l utilisation et l...

Page 6: ...t en aucun cas tre expos des temp ratures en dehors de la plage comprise entre 20 C 60 C 4 APPLICATIONS Le coffret de commande EC Drain 2x4 0 sert la commande automatique de deux pompes jusqu max P2 4...

Page 7: ...e manuel active la pompe 1 ou la pompe 2 ind pendamment du signal des interrupteurs flotteur avec toutes les fonctions de s curit comme la protection moteur lectro nique et la surveillance de la prote...

Page 8: ...tionnement test est activ ON ou d sactiv OFF par l interm diaire de l interrupteur DIP 6 Un fonctionnement test est activ pendant 2 s apr s une dur e d immobilisation des pompes de 24 h Alarme sonore...

Page 9: ...120 secondes DANGER Danger de mort Lors de travaux sur le coffret de commande ouvert il existe un risque d lectrocution par contact avec des composants sous tension Seul le personnel sp cialis est ha...

Page 10: ...utilis Introduire les extr mit s du c ble de la pompe dans les passe c bles vis et les entr es et les connecter conform ment aux symboles sur les r glettes bornes REMARQUE Apr s le serrage du passe c...

Page 11: ...ffectuer la mise en service par le service apr s vente Salmson Observer les notices de montage et de mise en service Avant de mettre l installation de pompe en service avec le coffret de commande EC D...

Page 12: ...PANNES CAUSES ET REM DES Ne faire effectuer le d pannage que par du personnel qualifi Observer les consignes de s curit au paragraphe 9 Entretien S il s av re impossible de supprimer la panne de fonct...

Page 13: ...installation operating and maintenance personnel must have the appropriate qualifications for this work The area of accountability responsibility and personnel monitoring are to be ensured by the oper...

Page 14: ...switches in potentially explosive areas In the case of usage in potentially explosive areas be sure to comply with all applicable explosion protection regulations The intended use includes complying w...

Page 15: ...ical and acoustic alarm signals are issued and the collective fault signal contact SSM and high water alarm con tact alarm are active If the automatic mode button is pressed the auto matic mode of bot...

Page 16: ...nger of electric shock by touching live components when working on the open switchgear This work may be carried out only by qualified person nel To change the DIP switch settings switch the unit so th...

Page 17: ...of installation from direct exposure to sun light Borehole distances 268 x 188 mm WxH For details see bottom of switchgear For fixation provide screws 4 screws max 4 mm and the corresponding dowels T...

Page 18: ...arm if the voltage drops or if the main switch is switched off Alarm terminals 14 15 16 Connection for external high water alarm potential free changeover contact Min contact load 12 V DC 10 mA Max co...

Page 19: ...ian Before carrying out maintenance or repair work observe the Decommissioning chapter The system operator must make sure all the maintenance inspection and installation work is performed by authorise...

Page 20: ...to the environment and risks to personal health are avoided by the proper disposal and appropriate recycling of this product 1 Draw on public or private waste management companies for the disposal of...

Page 21: ...Qualifica del personale Il personale addetto a montaggio impiego e manutenzione deve disporre dell apposita qualifica richiesta per questo tipo di lavori L utente deve farsi garante delle responsabil...

Page 22: ...dit e danneggiamenti meccanici Esso non deve essere esposto a temperature al di fuori del campo di 20 C 60 C 4 CAMPO D APPLICAZIONE L apparecchio di comando EC Drain 2x4 0 serve al comando automatico...

Page 23: ...seri mento della pompa 1 o della pompa 2 avverr indi pendentemente dal segnale degli interruttori a galleggiante con tutte le funzioni di sicurezza quali salvamotore elettronico e controllo del contat...

Page 24: ...onamento di prova viene atti vato ON o disattivato OFF tramite l interruttore DIP 6 Un funzionamento di prova viene effettuato per la durata di 2 s al termine di un tempo di inattivit delle pompe di 2...

Page 25: ...viene mediante regolazione continua nell arco di 0 120 secondi PERICOLO Pericolo di morte Durante i lavori sull apparecchio di comando aperto sussiste il pericolo di folgorazione da contatto con compo...

Page 26: ...lla designa zione riportata sulle barre morsettiere NOTA Dopo aver serrato il pressacavo accertarsi che il cavo si ben fisso Se il cavo allentato nel pressa cavo sostituire la guarnizione presente con...

Page 27: ...mson Prima di procedere alla messa in servizio dell impianto pompa con l apparecchio di comando EC Drain 2x4 0 verificare tutte le impostazioni tipo della tensione di rete posizioni degli interruttori...

Page 28: ...sere eliminati solo da personale tecnico qualificato Osservare le indicazioni di sicurezza descritte nel paragrafo 9 Manutenzione Nel caso non sia possibile eliminare l inconveniente rivolgersi all in...

Page 29: ...maci n de utilidad para el manejo del producto Tambi n puede indicar la presencia de posibles problemas Las indicaciones situadas directamente en el producto como p ej Flecha de sentido de giro identi...

Page 30: ...ANSPORTE Y ALMACENAMIENTO Inmediatamente despu s de la recepci n del producto Compruebe si el producto ha sufrido da os durante el trans porte Si el producto ha sufrido da os tome las medidas necesari...

Page 31: ...a para inundaciones Adem s se produce una activa ci n forzada de la bomba para aumentar la seguridad de la instalaci n Zumbador desconectado reset pos 4 Cuando se acciona el pulsador Funcionamiento ma...

Page 32: ...prueba c clica Esta marcha de prueba se activa ON o se desactiva OFF con el conmutador DIP 6 La marcha de prueba se activa durante 2 segundos tras un tiempo de parada de las bomba de 24 horas Zumbador...

Page 33: ...ro de electrocuci n por contacto con com ponentes conductores de corriente Las tareas de este tipo deben ser realizadas exclusiva mente por personal cualificado Para ajustar el potenci metro es precis...

Page 34: ...N Tras colocar el prensaestopas com pruebe que el cable queda fijo Si el cable queda suelto en el prensaestopas cambie la junta por la junta reductora suministrada paquete adicional Conecte la bomba l...

Page 35: ...oner en marcha el sistema con el cuadro EC Drain 2x4 0 es preciso comprobar todos los ajustes Tipo de tensi n de red Ajustes de los conmutadores DIP y ajuste de la corriente de la bomba v ase 6 2 3 y...

Page 36: ...icado en el cap tulo Puesta en mar cha 10 AVER AS CAUSAS Y SOLUCI N La subsanaci n de aver as debe correr a cargo exclusiva mente de personal cualificado Se deben respetar las indicaciones de segurida...

Page 37: ...POSTO Questo prodotto stato fabbricato in un sito certificato ISO 14 001 rispettoso dell ambiente Questo prodotto composto da materiali in grandissima parte riciclabile In fine di vita farlo eliminare...

Reviews: