11-179
TROUBLESHOOTING
2-8-2. Continuous water spray works, but intermittent water spray does not operate 1/2
Water spray mode select switch must be “ ”.
Water spray timer switch must be “ I ”.
Set water spray pump switch to “PUMP 2”.
Reference Fig. : 2-8-1
Check point
Check/Cause
Action
1. Water Spray Timer
(1) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray timer terminal 1, 3 inlet wires G and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray timer terminal 4 outlet wire GB and chassis
ground.
Standard voltage : 12 V or more
If above item (1) is OK and item (2) is NG with no
abnormality found in grounding of water spray timer, water
spray timer is faulty.
•
Replace water spray
timer.
2. Water Spray Timer
Switch
(1) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray timer switch terminal 2 inlet wire GL and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray timer switch terminal 3 outlet wire G and chassis
ground.
Standard voltage : 12 V or more
If above item (1) is OK and item (2) is NG, water spray
timer switch is faulty.
•
Replace water spray
timer switch.
3. water Spray Pump
(F, 2)
(1) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray pump relay (F, 2) terminal 1 inlet wire G and
chassis ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray pump relay (F, 2) terminal 5 inlet wire Lw and
chassis ground.
Standard voltage : 12 V or more
(3) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray pump relay (F, 2) terminal 3 outlet wire Gw and
chassis ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and item (3) is NG,
water spray pump (F, 2) is faulty.
•
Replace water spray
pump (F, 2).
•
•
•
Summary of Contents for SW880-1
Page 1: ...SW880 1 990 1 SHOP MANUAL 3498 6568A 0 ...
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...SAFETY ...
Page 16: ......
Page 24: ......
Page 25: ...SPECIFICATIONS ...
Page 26: ......
Page 27: ......
Page 31: ......
Page 39: ...ENGINE AND CONTROLS ...
Page 40: ......
Page 46: ......
Page 47: ...HYDRAULIC SYSTEMS ...
Page 48: ......
Page 49: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 59: ......
Page 68: ......
Page 70: ......
Page 72: ......
Page 76: ......
Page 78: ......
Page 82: ......
Page 83: ...ELECTRICAL SYSTEM ...
Page 84: ......
Page 88: ......
Page 90: ......
Page 92: ......
Page 94: ......
Page 125: ...VIBRATORY DRUM ...
Page 126: ......
Page 136: ......
Page 171: ...BRAKE ...
Page 172: ......
Page 175: ...OPERATOR STATION ...
Page 176: ......
Page 179: ...WATER SPRAY SYSTEM ...
Page 180: ......
Page 182: ......
Page 183: ...INSPECTION AND ADJUSTMENT ...
Page 184: ......
Page 209: ...TROUBLESHOOTING ...
Page 210: ......
Page 427: ......