11-053
TROUBLESHOOTING
2-4-1. Engine will not start (Starter motor does not run) 15/17
F-R lever must be in “N”.
Parking brake switch must be applied.
Foot brake switch must be ON (Brake pedal is not depressed).
Check whether exact meter multiple display shows any error code.
2) when display shows no error code
Reference Fig.: 2-4-1
Check point
Check/Cause
Action
6. Forward Switch
(1) when starter switch is ON, measure voltage between
forward switch terminal COM inlet wire wL and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is ON, measure voltage between
forward switch terminal NC outlet wire Bw and chassis
ground.
Standard voltage : 12 V or more
If above item (1) is OK and item (2) is NG, forward switch
is faulty.
•
Replace forward switch.
7. Reverse Switch
(1) when starter switch is ON, measure voltage between
reverse switch terminal COM inlet wire wG and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is ON, measure voltage between
reverse switch terminal NC outlet wire Gr and chassis
ground.
Standard voltage : 12 V or more
If above item (1) is OK and item (2) is NG, reverse switch
is faulty.
•
Replace reverse switch.
8. Interlock Relay
(1) when starter switch is ON, measure voltage between
interlock relay terminal 1 inlet wire Gr and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is ON, measure voltage between
interlock relay terminal 3 inlet wire BW and chassis
ground.
Standard voltage : 12 V or more
(3) when starter switch is ON, measure voltage between
interlock relay terminal 5 outlet wire P and chassis
ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and item (3) is NG,
interlock relay is faulty.
•
Replace interlock relay.
9. Starter Motor Relay
(1) when starter switch is ON, measure voltage between
starter motor relay terminal 1 inlet wire P and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is START, measure voltage
between Starter motor relay terminal 3 inlet wire LB and
chassis ground.
Standard voltage : 12 V or more
(3) when starter switch is START, measure voltage
between starter motor relay terminal 5 outlet wire Y and
chassis ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and item (3) is NG,
starter motor relay is faulty.
•
Replace starter motor
relay.
•
•
•
•
Summary of Contents for SW880-1
Page 1: ...SW880 1 990 1 SHOP MANUAL 3498 6568A 0 ...
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...SAFETY ...
Page 16: ......
Page 24: ......
Page 25: ...SPECIFICATIONS ...
Page 26: ......
Page 27: ......
Page 31: ......
Page 39: ...ENGINE AND CONTROLS ...
Page 40: ......
Page 46: ......
Page 47: ...HYDRAULIC SYSTEMS ...
Page 48: ......
Page 49: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 59: ......
Page 68: ......
Page 70: ......
Page 72: ......
Page 76: ......
Page 78: ......
Page 82: ......
Page 83: ...ELECTRICAL SYSTEM ...
Page 84: ......
Page 88: ......
Page 90: ......
Page 92: ......
Page 94: ......
Page 125: ...VIBRATORY DRUM ...
Page 126: ......
Page 136: ......
Page 171: ...BRAKE ...
Page 172: ......
Page 175: ...OPERATOR STATION ...
Page 176: ......
Page 179: ...WATER SPRAY SYSTEM ...
Page 180: ......
Page 182: ......
Page 183: ...INSPECTION AND ADJUSTMENT ...
Page 184: ......
Page 209: ...TROUBLESHOOTING ...
Page 210: ......
Page 427: ......