11-135
TROUBLESHOOTING
2-6-2. Vibration frequency cannot be switched 1/3
Set vibration mode select switch to “ ” (continuous mode).
Vibration frequency select switch is fixed at 4000 vpm, vibration change switch is “
” when frequency
cannot be switched.
Check whether exact meter multiple display shows any error code.
Reference Fig.: 2-6-1
Error code
Check point
Check/Cause
Action
E21
1. Connector
Check vibration frequency select switch, vibration change
switch and traveling controller connector terminal 31, 32,
33 for corrosion, breakage, bending and looseness.
If any abnormality is found, connector is faulty.
•
•
Replace connector
or terminal.
2. Harness
(1) Measure resistances between switches and traveling
controller terminal wires.
Vibration frequency select switch terminal 3 wire G and
traveling controller terminal 31 wire G
Vibration frequency select switch terminal 6 wire L and
traveling controller terminal 32 wire L
Vibration change switch terminal 2 wire Br and traveling
controller terminal 33 wire Br.
Standard resistance : 10 Ω or less
(2) Measure resistances between switches and fuse box
terminal wires.
Vibration frequency select switch terminal 1, 4 wires
YW, vibration change switch terminal 1 wire YW and
fuse box terminal 8 wire YW.
Standard resistance : 10 Ω or less
If resistance is abnormal, harness is faulty.
•
•
•
•
•
Repair or replace
harness.
3. Vibration
Frequency
Select Switch
(1) when starter switch is ON, measure voltage between
vibration frequency select switch terminal 1, 4 inlet
wires YW and chassis ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and vibration frequency
select switch is “2500”, measure voltage between
vibration frequency select switch terminal 6 outlet wire L
and chassis ground.
Standard voltage : 12 V or more
(3) when starter switch is ON and vibration frequency
select switch is “3000”, measure voltage between
vibration frequency select switch terminal wires and
chassis ground.
Vibration frequency select switch terminal 3 outlet wire
G and chassis ground.
Vibration frequency select switch terminal 6 outlet wire
L and chassis ground.
Standard voltage : 12 V or more
(4) when starter switch is ON and vibration frequency
select switch is “4000”, measure voltage between
vibration frequency select switch terminal 3 outlet wire
G and chassis ground.
Standard voltage : 12 V or more
If above item (1) is OK and any of items (2) through (4) is
NG, vibration frequency select switch is faulty.
•
•
•
Replace vibration
frequency select
switch.
•
•
•
Summary of Contents for SW880-1
Page 1: ...SW880 1 990 1 SHOP MANUAL 3498 6568A 0 ...
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...SAFETY ...
Page 16: ......
Page 24: ......
Page 25: ...SPECIFICATIONS ...
Page 26: ......
Page 27: ......
Page 31: ......
Page 39: ...ENGINE AND CONTROLS ...
Page 40: ......
Page 46: ......
Page 47: ...HYDRAULIC SYSTEMS ...
Page 48: ......
Page 49: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 59: ......
Page 68: ......
Page 70: ......
Page 72: ......
Page 76: ......
Page 78: ......
Page 82: ......
Page 83: ...ELECTRICAL SYSTEM ...
Page 84: ......
Page 88: ......
Page 90: ......
Page 92: ......
Page 94: ......
Page 125: ...VIBRATORY DRUM ...
Page 126: ......
Page 136: ......
Page 171: ...BRAKE ...
Page 172: ......
Page 175: ...OPERATOR STATION ...
Page 176: ......
Page 179: ...WATER SPRAY SYSTEM ...
Page 180: ......
Page 182: ......
Page 183: ...INSPECTION AND ADJUSTMENT ...
Page 184: ......
Page 209: ...TROUBLESHOOTING ...
Page 210: ......
Page 427: ......