10-079
TROUBLESHOOTING
3-3-2. Vibrator frequency is too low
Check point
Cause
Check/Action
1. Oil Level of
Hydraulic Oil Tank
Oil level in hydraulic oil tank is low.
Fill tank until correct oil level is obtained.
2. Suction Filter for
Vibrator Pump
Flow rate of vibrator pump decreases as
well as charge pressure decreases due to
clogged filter.
Clean suction filter or replace it if necessary.
3. Vibrator Motor
Vibrator motor inlet pressure is low.
Measure vibrator motor inlet pressure.
If low, check and adjust high pressure
relief valve or replace it if necessary.
•
•
Vibrator circuit pressure is not held in
vibrator motor case.
Measure vibrator motor case pressure.
If case pressure is not within allowable
pressure, repair vibrator motor or replace it
if necessary.
•
•
Decrease in vibrator motor rpm due to
internal leakage in vibrator motor.
Measure drain quantity from vibrator motor.
If drain quantity is larger than standard
value, repair vibrator motor or replace it if
necessary.
•
•
4. Vibrator Pump
Insufficient discharge rate from vibrator
pump due to reduced efficiency of vibrator
pump.
Measure discharge flow rate of vibrator
pump with flow meter.
If discharge flow rate is not within specified
range, repair vibrator pump or replace it if
necessary.
•
•
Insufficient pump discharge due to wear of
vibrator pump drive shaft spline.
Replace vibrator pump.
3-3-3. Vibratory drum does not changeover vibrating (SW354 ROPS)
Check point
Cause
Check/Action
1. Vibrator Solenoid
Valve
Vibratory drum does not changeover
vibrating because spool of vibrator solenoid
valve does not change.
Repair vibrator solenoid valve or replace it if
necessary.
3-3-4. Vibration mode does not switch (TW504)
Check point
Cause
Check/Action
1. Vibrator Solenoid
Valve
Vibrator solenoid valve spool does not
change.
Repair vibrator solenoid valve or replace it if
necessary.
3-3-5. Vibrator does not stop
Check point
Cause
Check/Action
1. Vibrator Solenoid
Valve (SW/TW354)
Vibrator solenoid valve spool does not
change.
Repair vibrator solenoid valve or replace it if
necessary.
2. Vibrator Solenoid
Valve (TW504)
Vibrator solenoid valve spool does not
return to neutral position.
Repair vibrator solenoid valve or replace it if
necessary.
Summary of Contents for SW354
Page 1: ...SW TW354 SW TW504 SHOP MANUAL 3498 6446A 1 ...
Page 2: ......
Page 4: ......
Page 17: ...SAFETY ...
Page 18: ......
Page 26: ......
Page 27: ...SPECIFICATIONS ...
Page 28: ......
Page 29: ......
Page 56: ......
Page 57: ...ENGINE AND CONTROLS ...
Page 58: ......
Page 64: ......
Page 72: ......
Page 73: ...HYDRAULIC SYSTEMS ...
Page 74: ......
Page 75: ......
Page 78: ......
Page 80: ......
Page 82: ......
Page 84: ......
Page 86: ......
Page 88: ......
Page 90: ......
Page 92: ......
Page 94: ......
Page 95: ......
Page 104: ......
Page 106: ......
Page 108: ......
Page 116: ......
Page 118: ......
Page 122: ......
Page 124: ......
Page 126: ......
Page 127: ......
Page 132: ......
Page 136: ......
Page 138: ......
Page 140: ......
Page 141: ...ELECTRICAL SYSTEM ...
Page 142: ......
Page 146: ......
Page 148: ......
Page 150: ......
Page 152: ......
Page 154: ......
Page 156: ......
Page 158: ......
Page 160: ......
Page 162: ......
Page 164: ......
Page 166: ......
Page 178: ......
Page 202: ......
Page 204: ......
Page 206: ......
Page 247: ...VIBRATORY DRUM REAR WHEEL ...
Page 248: ......
Page 256: ......
Page 258: ......
Page 296: ......
Page 297: ...BRAKE ...
Page 298: ......
Page 302: ......
Page 303: ...WATER SPRAY SYSTEM ...
Page 304: ......
Page 306: ......
Page 308: ......
Page 310: ......
Page 311: ...INSPECTION AND ADJUSTMENT ...
Page 312: ......
Page 347: ...TROUBLESHOOTING ...
Page 348: ......
Page 359: ......
Page 450: ......
Page 451: ...10 101 TROUBLESHOOTING SW504 4 3 Propulsion Refer to P 10 022 ...
Page 460: ......
Page 478: ...10 127 TROUBLESHOOTING SW504 5 HYDRAULIC SYSTEM TROUBLESHOOTING SW504 Refer to P 10 073 ...
Page 479: ......