9-031
ELECTRICAL SYSTEM TROUBLESHOOTING
2-5-3. Hour meter is abnormal
The other lamps light correctly.
Reference Fig. : 2-5
Check point
Check/Cause
Action
1. Hour Meter
- When turning starter switch ON, measure voltage between
hour meter plus (+) terminal YG wire and chassis ground.
Standard voltage: 12 V or more
- If above measurement is normal, the hour meter is faulty.
Replace the
combination meter.
2. Harness Connecting
Between Terminals
- Check harness between terminals for continuity.
- No continuity indicates that harness is open or poorly
connected.
Repair or replace the
harness.
2-5-4. Temperature gauge is abnormal
The other lamps light correctly.
Reference Fig. : 2-5
Check point
Check/Cause
Action
1. Thermo-unit
- Disconnect harness and measure resistance of thermo-unit.
Standard resistance:
158 Ω (when unit temperature is 50°C, 122°F)
29 Ω (when unit temperature is 103°C, 217°F)
- If measured resistance is abnormal, the thermo-unit is faulty.
Replace the thermo-
unit.
2. Temperature Gauge - When turning starter switch ON, measure voltage between
temperature gauge plus (+) terminal WR wire and chassis
ground.
Standard voltage: 12 V or more
- If the above is OK, and there is no problem with the thermo-
unit, then the thermometer is faulty.
Replace the
combination meter.
3. Harness Connecting
Between Terminals
- Check harness between terminals for continuity.
- No continuity indicates that harness is open or poorly
connected.
Repair or replace the
harness.
2-5-5. Fuel gauge is abnormal
The other lamps light correctly.
Reference Fig. : 2-5
Check point
Check/Cause
Action
1. Fuel-unit
- Disconnect harness and measure resistance of fuel-unit.
18 Ω (when float is at FULL position)
83 Ω (when float is at EMPTY position)
- If measured resistance is abnormal, the fuel-unit is faulty.
Replace the fuel-
unit.
2. Fuel Gauge
- When turning starter switch ON, measure voltage between fuel
gauge plus (+) terminal WR wire and chassis ground.
Standard voltage: 12 V or more
- If the above is OK, and there is no problem with the fuel unit,
then the fuel gauge is faulty.
Replace the
combination meter.
3. Harness Connecting
Between Terminals
- Check harness between terminals for continuity.
- No continuity indicates that harness is open or poorly
connected.
Repair or replace the
harness.
•
•
•
Summary of Contents for SV400D-2
Page 1: ...SV400 2 SHOP MANUAL 0404 99027 0 31649 B ...
Page 2: ......
Page 4: ......
Page 11: ...SAFETY ...
Page 12: ......
Page 19: ...SPECIFICATIONS ...
Page 20: ......
Page 36: ......
Page 37: ...ENGINE AND CONTROLS ...
Page 38: ......
Page 46: ......
Page 47: ...HYDRAULIC SYSTEMS ...
Page 48: ......
Page 49: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 60: ......
Page 61: ......
Page 70: ......
Page 72: ......
Page 74: ......
Page 76: ......
Page 78: ......
Page 84: ......
Page 86: ......
Page 90: ......
Page 91: ...ELECTRICAL SYSTEM ...
Page 92: ......
Page 94: ......
Page 96: ......
Page 101: ...VIBRATORY DRUM REAR AXLE ...
Page 102: ......
Page 108: ......
Page 110: ......
Page 126: ......
Page 132: ......
Page 133: ...BRAKES ...
Page 134: ......
Page 136: ......
Page 138: ......
Page 140: ......
Page 147: ...INSPECTION AND ADJUSTMENT ...
Page 148: ......
Page 166: ......
Page 167: ...TROUBLESHOOTING ...
Page 168: ......