21.0 Greasing the Carriage Continued
Figure 22: Type L grease fitting, supplied with THK MG70 grease kit.
22.0 Reassembly Procedure
Reassembly is done in exactly the reverse of the disassembly procedure. The small diameter pneumatic tubing
may require slight position adjustment to prevent pinching during attachment of the right side Case. Careful-
ly observe the tubing to see if it is pinched or trapped between parts while the right side Case is re-installed.
Tubing can be damaged (cut or torn) if it is pinched during reassembly. The tool will not operate properly if the
tubing is pinched or cut during reassembly.
Place the right side Case into position on the assembly. It should engage easily with the left side Case, without
any need to force the parts into position. Before installing screws, observe the joint between the left and right
side Cases to confirm that they are properly aligned with each other and the two Case halves are in contact.
Once this is confirmed, insert the 8 screws that attach the right side Case and seat them to a very light snug
condition. Once more, confirm the position of the right side Case by looking for a uniform joint between the two
Case halves. Once this in confirmed, snug the eight (8) screws to complete the reassembly process. Be careful
not to over-tighten.
23.0 Functional Confirmation
The air supply should still be disconnected at this point. If jaws are installed in the tool, ensure they are both
fully seated in their respective carriers. Jaws are not required for this functional confirmation, so they may be
removed if desired.
With the air supply still disconnected, open and close the Safety Cover and latch to confirm proper motion for
both. Be observant for binding or for failure of the Safety Cover to fully close. Test that the Latch engages and
locks the Safety Cover in the closed position.
Confirm that the air supply does not exceed the maximum allowed value of 100 psi.