BATTERY PANEL

9

OPERATION

Mute the alarm sound
The alarm sound is muted by pressing ‘MUTE/TEST’.
A new event will reactivate the alarm sound.

Switch between batteries
To switch between Battery 1 and Battery 2, press ‘BATT 1-2’ briefly.
Applicable for 2 battery installations.

Test the Battery Panel
Press ‘MUTE/TEST’ for 2 seconds to initiate a self test.
All lamps, backlight and alarm sound are activated.

Adjust the light intensity
Press ‘DIM’ to adjust the light intensity.
The dimmer button controls the intensity of the lamps and backlight in
four levels. The light in the alarm lamps can not be turned fully off.

4-0-34932

OPERATION

Summary of Contents for BP4680

Page 1: ...SAILOR Battery Panel BP4680 Technical Manual M4680GB0 0 p65 10 12 99 09 21 1...

Page 2: ...documentation is disclaimed The information in this manual is furnished for informational use only is subject to change without notice may contain errors or inaccuracies and represents no commitment...

Page 3: ...TENTS INTRODUCTION 5 General Description 5 Technical Data 7 OPERATION 9 INSTALLATION 10 Wiring principle 10 Outline and Mounting Plan 11 Connectors Location 11 Adjustments 12 Disassemble for jumper se...

Page 4: ...4 BATTERY PANEL...

Page 5: ...rm lamps for indication of AC supply failure for each battery charger With a push button switch it is possible to switch the panel meters between monitoring battery 1 and battery 2 in two battery inst...

Page 6: ...supplied from the battery itself and will operate down to a battery voltage of 10 V The audible alarm and visual indicators are supplied from the 24 V DC of the AC Power Supply Charger allowing low vo...

Page 7: ...or voltage input Relay contact No Alarm open circuit Alarm short circuit Open circuit voltage 1 2V Short circuit current 6mA Voltage input No Alarm 24V DC nom Alarm 0V DC Input current at 24 V DC 6mA...

Page 8: ...1V Accuracy 4 typically Measuring range 10 to 40V Sensitivity 1V V Current Meter 3 digit Resolution 0 1Amp Accuracy 10 of meter reading Measuring range 200 Amp Sensitivity 100 V Amp Compass safe dista...

Page 9: ...BATT 1 2 briefly Applicable for 2 battery installations Test the Battery Panel Press MUTE TEST for 2 seconds to initiate a self test All lamps backlight and alarm sound are activated Adjust the light...

Page 10: ...p i r c s e D n o i t p i r c s e D n o i t p i r c s e D 1 T A B V y l p p u s d n a t u p n i r e t e m t l o V 2 T N U H S t u p n i r e t e m t n e r r u C e c n e r e f e r 3 T N U H S t u p n i...

Page 11: ...BATTERY PANEL 11 OUTLINE AND MOUNTING PLAN 3 0 33418 Dimensions are in mm Tolerance 1 Weight 1 3 Kg 1 Space for cable entry min 100 CONNECTORS LOCATION 4 0 34931 INSTALLATION...

Page 12: ...t R84 see figure pos 1 until high battery alarm is indicated 3 Decrease the input voltage by 0 5V and check that the alarm stops If not repeat the adjustment Adjustment of Low voltage alarm threshold...

Page 13: ...cated 3 Decrease the input voltage by 0 5V and check that the alarm stops If not repeat the adjustment Adjustment of Low voltage alarm threshold for Battery 2 1 Apply an input voltage set to the wante...

Page 14: ...b connectors 3 Carefully seperate the rear cover from the front 4 Disconnect the 4 ribboncables from the PCB inside the rear cover 5 Remover the 5 screws holding the PCB and take out the PCB 6 Re conn...

Page 15: ...figure jumpers S3 and S7 pos 5 are shown in the relay contact position 1 To change to the voltage input both S3 and S7 must be set to the oposite position 2 Apply an input voltage to the X1 terminals...

Page 16: ...no voltage gives alarm and that the alarm stops when 24V DC is applied Setting of single or dual battery On the figure jumper S8 pos 7 is shown in dual battery position 1 To change to single battery...