background image

BATTERY PANEL

3

TABLE OF CONTENTS

INTRODUCTION ................................................ 5
General Description ............................................ 5
Technical Data ................................................... 7

OPERATION ...................................................... 9

INSTALLATION ............................................... 10
Wiring principle ................................................. 10
Outline and Mounting Plan ............................... 11
Connectors Location ......................................... 11
Adjustments ...................................................... 12
Disassemble for jumper setting ........................ 14
Jumper Settings ............................................... 15

Summary of Contents for BP4680

Page 1: ...SAILOR Battery Panel BP4680 Technical Manual M4680GB0 0 p65 10 12 99 09 21 1...

Page 2: ...documentation is disclaimed The information in this manual is furnished for informational use only is subject to change without notice may contain errors or inaccuracies and represents no commitment...

Page 3: ...TENTS INTRODUCTION 5 General Description 5 Technical Data 7 OPERATION 9 INSTALLATION 10 Wiring principle 10 Outline and Mounting Plan 11 Connectors Location 11 Adjustments 12 Disassemble for jumper se...

Page 4: ...4 BATTERY PANEL...

Page 5: ...rm lamps for indication of AC supply failure for each battery charger With a push button switch it is possible to switch the panel meters between monitoring battery 1 and battery 2 in two battery inst...

Page 6: ...supplied from the battery itself and will operate down to a battery voltage of 10 V The audible alarm and visual indicators are supplied from the 24 V DC of the AC Power Supply Charger allowing low vo...

Page 7: ...or voltage input Relay contact No Alarm open circuit Alarm short circuit Open circuit voltage 1 2V Short circuit current 6mA Voltage input No Alarm 24V DC nom Alarm 0V DC Input current at 24 V DC 6mA...

Page 8: ...1V Accuracy 4 typically Measuring range 10 to 40V Sensitivity 1V V Current Meter 3 digit Resolution 0 1Amp Accuracy 10 of meter reading Measuring range 200 Amp Sensitivity 100 V Amp Compass safe dista...

Page 9: ...BATT 1 2 briefly Applicable for 2 battery installations Test the Battery Panel Press MUTE TEST for 2 seconds to initiate a self test All lamps backlight and alarm sound are activated Adjust the light...

Page 10: ...p i r c s e D n o i t p i r c s e D n o i t p i r c s e D 1 T A B V y l p p u s d n a t u p n i r e t e m t l o V 2 T N U H S t u p n i r e t e m t n e r r u C e c n e r e f e r 3 T N U H S t u p n i...

Page 11: ...BATTERY PANEL 11 OUTLINE AND MOUNTING PLAN 3 0 33418 Dimensions are in mm Tolerance 1 Weight 1 3 Kg 1 Space for cable entry min 100 CONNECTORS LOCATION 4 0 34931 INSTALLATION...

Page 12: ...t R84 see figure pos 1 until high battery alarm is indicated 3 Decrease the input voltage by 0 5V and check that the alarm stops If not repeat the adjustment Adjustment of Low voltage alarm threshold...

Page 13: ...cated 3 Decrease the input voltage by 0 5V and check that the alarm stops If not repeat the adjustment Adjustment of Low voltage alarm threshold for Battery 2 1 Apply an input voltage set to the wante...

Page 14: ...b connectors 3 Carefully seperate the rear cover from the front 4 Disconnect the 4 ribboncables from the PCB inside the rear cover 5 Remover the 5 screws holding the PCB and take out the PCB 6 Re conn...

Page 15: ...figure jumpers S3 and S7 pos 5 are shown in the relay contact position 1 To change to the voltage input both S3 and S7 must be set to the oposite position 2 Apply an input voltage to the X1 terminals...

Page 16: ...no voltage gives alarm and that the alarm stops when 24V DC is applied Setting of single or dual battery On the figure jumper S8 pos 7 is shown in dual battery position 1 To change to single battery...