background image

-  18  -

5. TECHNICAL SPECIFICATIONS

6. INSTALATION

1

1

6

14

12

10

13

11

16

15

2

8

3

4

5

7

9

INCORRECT INSTALLATION OF THE MACHINE MAY 

CAUSE DAMAGE TO PEOPLE, ANIMALS OR 

OBJECTS. THE  MANUFACTURER CANNOT BE 

CONSIDERED RESPONSIBLE FOR THESE DAMAGES

6.1. ARRANGEMENT OF THE LIGHTING SYSTEM

The Client must make sure that there is suitable 

lighting for the surroundings and that the lighting 

conforms to the regulations in force. In particular, 

the Client must arrange the positioning of lighting 

that illuminates all the working area.

6.2. ARRANGEMENT OF THE PNEUMATIC 

SYSTEM

The Client must arrange a line of filtered com-

pressed air supplied by a compressor that is 

suitable for the consumption required. Do not use 

compressed air that contains chemical products, 

synthetic oil with organic solvents, salts or corro-

sive gases as they can cause damage or malfunc-

tioning. The line of compressed air must arrive up 

to the supply points of the machine. If the com-

pressed air contains a large amount of moisture, 

it may cause malfunctioning in the valves and in 

the pneumatic components. Install a moisture 

separator downstream from the compressor to 

avoid this.

6.3. CLASSIFICATION ACCORDING TO THE ATEX 

DIRECTIVE

The machine conforms to the essential requisites 

of the EU Directive 94/9/EC, better known as 

ATEX (“Explosive Atmospheres”). It is classified 

as group II category 3 letter G system. The 

assessment procedures of conformity, carried out 

by an internal factory check, allow the installa-

tion of the machine in surroundings where there 

may be potentially explosive atmospheres due to 

the presence of gas, fumes or mist.

6.4. POSITIONING

The Double 250 must be positioned in a well-ai-

red place.
The area must be equipped with all means provi-

ded for by the Italian Legislative each country 

with reference to the health and safety of the 

workers in the working environment.
Position the machine on the floor and make sure 

that there is sufficient space around the machine 

to carry out normal maintenance operations or 

inspections.

Summary of Contents for DOBLE 250

Page 1: ...m a n u a l d e i n s t r u c c i o n e s i n s t r u c t i o n m a n u a l doble...

Page 2: ......

Page 3: ...descarga de agua sucia del tanque p g 6 4 4 Sistema de aspiraci n p g 6 4 5 Limpieza manual con el cepillo p g 6 4 6 Aclarado manual con disolvente p g 6 5 Especificaciones t cnicas p g 7 5 1 Datos t...

Page 4: ...lativo 626 94 sobre la obligaci n de la capacitaci n del personal en la introducci n de nuevos siste mas de trabajo En particular los usuarios tambi n deben ser instruidos sobre la base de este manual...

Page 5: ...es posible durante las fases de instalaci n mantenimiento y desmantelamiento En todos los casos el personal que utilice la m quina aunque s lo sea de vez en cuando debe responder a los requisitos desc...

Page 6: ...ntre la placa de filtro y el prefiltro de malla de acero inoxidable 5 Abra el grifo de descarga del tanque girando el mango hacia la derecha y en una direcci n horizontal 6 Espere a la descarga comple...

Page 7: ...e del tanque de lavado El lavado de las piezas que se ensucien con pintura se lleva a cabo de forma manual con el cepillo atomizador Dentro de esta cabina lado derecho hay un cepillo atomizador con un...

Page 8: ...de suministro de la m quina Si el aire comprimido contiene una gran cantidad de humedad puede causar un mal funcionamien to en las v lvulas y en los componentes neum ti cos Instale un separador de hum...

Page 9: ...Aseg rese de que el tanque de filtrado quede firmemente colocado encima de los soportes Aseg rese de que stos soportes se fijan firmemente al tanque de recogida y proporcionan estabilidad para el tanq...

Page 10: ...cogida est vac o porque la manta filtrante est sucia no filtra Remedio Desenchufe el extremo del tubo de la bomba y hacer que el aire haga el camino inverso Introduzca el tubo de aspiraci n en el inte...

Page 11: ...rabajo y las Normativas vigentes Utilice guantes Si durante la utilizaci n de la lavadora el nivel sonoro ambiental sobrepasa 90 dB Es recomenda ble el uso de protectores ac sticos homologados La lava...

Page 12: ...10 DECLARACI N DE CONFORMIDAD Seg n la directiva 89 392 CE Anexo II Apartado A de fecha 14 de junio de 1989 Fabricante SAGOLA S A Direcci n Calle Urartea 6 01010 VITORIA GASTEIZ lava ESPA A Declaramo...

Page 13: ...er discharge from the tank page 16 4 4 Aspiration system page 16 4 5 Manual cleaning with brush page 16 4 6 Manual rinsing with atomized use of solvent page 16 5 Technical specifications page 17 5 1 T...

Page 14: ...tle III of Legis lative Decree 626 94 on the obligation of staff training when introducing new working systems In particular the users must also be instructed based on this user and maintenance manual...

Page 15: ...installation maintenan ce and dismantling In all instances the staff that use the machine occasionally must answer to the requisites described in the previous paragraph 3 6 INCORRECT USE OF THE MACHIN...

Page 16: ...d correctly halfway between the filter plate and the pre filter in stainless steel mesh 5 Open the tank discharge tap turning the relative handle in a clockwise direction and in a horizontal direction...

Page 17: ...g of parts that are dirtied with paint takes place manually with the atomizer brush Inside this cabin right hand side there is an atomizer brush with a relative drip course which allows the cleaning o...

Page 18: ...e supply points of the machine If the com pressed air contains a large amount of moisture it may cause malfunctioning in the valves and in the pneumatic components Install a moisture separator downstr...

Page 19: ...n basin and the filter basin 7 Make sure that the filter basin is positioned firmly above the supports for the filtering basin Make sure that these supports are inserted and welded firmly to the colle...

Page 20: ...mpty because the filter in non woven fabric is blocked it doesn t filter Remedy Plug the end of the tube and make it do the reverse air path Insert the aspiration tube inside the lower collection tank...

Page 21: ...ental regulations and characteristics for the Work Centre Use gloves If during use of the washing machine the environmental audible level rises over 90 dB the use of approved acoustic protectors is re...

Page 22: ...without notice 11 GUARANTEE CONDITIONS 12 DECLARATION OF CONFORMITY According to the directive 89 392 EEC Annex II Section A dated 14th of June 1989 Manufacturer SAGOLA S A Address Calle Urartea 6 010...

Page 23: ...at Kaufdatum Data de Compra Data di aacquisto E mail Tel Fax Sello Stamp Cachet Stempel Selo Timbro GUARANTEE C0NDITIONS CONDITIONS DE GARANTIE CONDICIONES DE GARANT A CONDI ES DA GARANTIA CONDIZIONI...

Page 24: ...PARATION PROFESSIONNELLE TECHNISCHER DIENST PROFESSIONNELLE REPARATURGARANTIE SERVI O DE ASSIST NCIA T CNICA GARANT A DE REPARA AO PROFISSIONAL SERVIZIO DI ASSISTENZA TECNICA GARANZIA DI RIPARAZIONE P...

Reviews: