31
Product will not
operate. LEDs
continuously blink
three times.
Cd57
Time from max level to min
level is too short.
Conflicting water level
readings (min and max level
being read at the same time).
Ensure that there are no leaks in the
sump.
Ensure that the floats are moving freely
within the sump.
Ensure that the product is level.
Product will not
operate. LEDs
continuously blink
once every 8
seconds on one
side.
Cd58
Overflow Detection on side
that is blinking.
Switch off the product and the water
supply.
Contact your dealer for assistance.
Little or No Mist
Generation
---
Transducer not operating
correctly.
Transducer is dirty.
Transducer is not sitting
correctly in sump.
Fan is obstructed or blocked.
Nozzle Is not on sump
correctly.
Nozze is blocked.
Check operation of transducer.
Clean sump and transducer
thoroughly.
Switch off product, take nozzle off
sump and ensure transducer is fitted in
sump correctly.
Remove air filter and clean. Ensure it is
placed back in product correctly.
Ensure nozzle is sitting on sump
correctly.
Clean sump, transducer and nozzle
thoroughly.
The flame effect has
too much smoke.
---
Flame effect setting is too
high.
Turn down the flame effect. Give the
product time to adjust to the new
setting.
Bluetooth Receiver
stops working.
---
Loose connection.
Check connection to jack (Fig. 12).
Remote Control
stops working.
---
Bluetooth range issue.
Bluetooth Receiver
connection is loose.
Remote control batteries need
replacing.
Check positioning of Bluetooth
Receiver.
Ensure it is not encased in metal or
concrete.
Check connection to jack (Fig. 12).
Replace batteries with two new AAA
batteries.