25
3. If the current time corresponds to an inactive time period, the current time will be shown along with a
flashing ‘Off’ symbol (Fig. D). The product will switch on at the next preset ‘On’ time period. Select
the flashing ‘Off’ symbol using ‘Button 6 –
Enter’ to switch off the timer.
-
Resetting Product Errors
The remote control can be used to reset some product errors. If the product is being supplied by a
water tank via a pump, a low water error or fill time error will be seen when the water tank runs empty.
The product will turn off and flash its lights. The error code (Cd51 for low water, Cd56 for fill time) will
also be displayed on the remote control. These error codes can be reset by following steps below.
1.
Activate the remote and navigate to the error code at the top of the screen using ‘Button 5 –
Arrows’ (Fig. A).
2.
When the error code is flashing, select the error by pressing ‘Button 6 –
Enter’.
3.
The reset menu will then be displayed (Fig. B). Press and hold ‘Button 6 –
Enter’ for three seconds
to reset the error (Fig. C).
4.
The error will be reset, the product will restart and the default home screen will be shown on the
remote control display (Fig. D).
Note, the water leak error (Cd57) and overflow error (Cd58) cannot be reset via the remote
control . Please refer to the
‘Troubleshooting’ section below for more details on these errors.
•