SAFIRE 2400Di, 2600Di, 3200Di and 3600Di Diesel / fuel oil heaters
2
USAGE, INSTALLATION AND MAINTENANCE
January 2012
SF_ Lämmitin Oy
Tilhenkatu 1 20610 Turku Finland Puh/Fax +358(0)2-2443282
INSTALLATION
Mounting bracket
Screw the heater’s mounting bracket to its place so that the heater is set in a horizontal position.
Pump and fuel hose
Attach the fuel pump in an upright position close to the fuel tank but above the fuel level, the
suction downwards. Max high between tank and heater 2m. If you need to pass the fuel hose
and the pump’s power supply cable through narrow gaps, disconnect the hose connector
above the pump and unplug the power supply cable from the pump’s connection terminal (the
polarity is insignificant). Attach the fuel hose carefully so that it won’t vibrate or rub against
anything. Don’t attach the pump too tight; this may cause disturbing noise.
Fuel tank connection
The fuel is conducted with a suction hose either from a separate tank (15, 22 or 30 litres) using a suitable
tank connection, or from a diesel tank by using a tank connection kit. Install a shut-off to the tank connection
if the fuel level in the tank or in the fuel hose can rise above the pump. Attach the fuel hoses carefully and
protect them from heat or mechanical strain.
Exhaust outlet
Exhaust is led out and combustion air taken in through hull with a coaxial
exhaust outlet.
For installing the outlet you need to make one Ø 50 mm hole and four 5,5 mm
holes (use the outlet end as a model). Cut the inner pipe a bit too long, so that
it can’t slip from its place. Bend the exhaust outlet hose as shown in the picture
and make a little hole on the
outer
hose, on the lowest part.
This way the condensation water can trip away.
Max. length of exhaust tube is 2m fir 2400Di, 2600Di and 3200Di and 1,5m for 3600Di.
Thermostat
Place the thermostat’s sensor to a place where it can measure the temperature
in the room in the best way. If you are using a GENIUS control panel, you can
connect two thermostats to the heater; one to be used during the night in the
sleeping cabin and one for the daytime to be used in the front cabin.
Controll panels
SAFIRE 3000
Place the control panel so that the display is easy to see and use, and that there’s no danger of starting the
heater by accident. The basic control panel can be either surface or flush mounted. The GENIUS control
panel is designed to surface mounting only. Attach the control panel to the heater with an included cable.
SAFIRE
BACK
OK
Hallinta
Ajastin
Asetukset
Termostaattin ytt
Made in Finland by
SF-L mmitin Oy
genius