Connect the charger to the grinder / charging outlet on the unit then to the mains.
The battery is fully charged after about 1 hour (if completely discharged).
After charging is completed the charger can be disconnected.
The battery shall be charged every 6 months, if the unit is not in use.
Blinking signal*
Error description
Troubleshooting
1 x Blinking,
2 sec pause
No battery or defect battery. Please check charger cable and connector
for damage and the 15A fuse on Econect.
2 x Blinking,
2 sec pause
Battery voltage is too high.
3 x Blinking,
2 sec pause
Battery temperature is
under 0°C or over 45°C.
Please let the unit cool or heat to the right
temperature, charging will start
automatically.
5 x Blinking,
2 sec pause
Device temperature is
too high.
Please turn off the charger and give it
some time to cool down.
1. Infrared-LED, For factory programing only.
2. Mains, indicating that mains are connected and the charger is on.
3. Red Error-LED, indicating different errors by flashing, see chart 1.
4. Yellow Charging-LED, indicating when the charger is charging the battery.
5. Green Full-LED, indicating when battery is fully charged.
1
2
3
4 5
* Blinking signals in continuous loop.
Chart 1.
CHARGING THE BATTERY CAN ONLY BE CARRIED OUT BETWEEN 0°C to +45°C
NOTICE
CHARGING THE BATTERY
8
If the batteries are left uncharged, they may be damaged.
CAUTION