TROUBLESHOOTING
12
ERROR INDICATIONS ON THE UNIT:
ERROR led is lit
- The temperature of the battery is over +55 °C.
Action:
Wait until the light goes out, then the temperature dropped and it is
possible to braze again.
ERROR led flashes
- The temperature of the battery is below +10 °C.
Action
: Leave the unit on, the built-in heating element will heat up the battery.
Wait until light goes out and the temperature has risen, and it is possible to braze.
ERROR and LOW BATTERY led flashes
- The temperature of the battery is below +10 °C and the battery is almost discharged.
Action:
Charge the batteries.
ERROR Led is lit after a braze
- The pin brazing was not complete.
Action:
The braze should be remade to achieve good results.
The Led turns off after 8 seconds.
ERROR Led glows
- Failure of a sensor in the unit.
Action:
The unit should be sent for repair.
LOW BATTERY Led flashes
- Battery is almost discharged.
LOW BATTERY led is lit
- Battery are discharged.
Action:
Charge the batteries.
Nothing happen when you press the buttons
- The electronics may have gotten stuck.
Action:
Remove control 5A fuse for a short time, put it back again.
The brazing never stops
- The electronics may have gotten stuck.
Action:
Remove the gun and the ground magnet from the rails and
disconnect them from the unit as soon as possible.
Remove the control 5A fuse, check that nothing has been damaged
before putting the fuse back.
Summary of Contents for ECONECT PinBrazing
Page 22: ...22 NOTEPAD ...