SAFEGREASE, SAFEOIL
ST-1100i
110i1CEN.doc
16.04.2003 Rev. 1C
5 (14)
Pressure discharge
In pressure transmitter operation, line pressure discharge is measured and new pressurization
can be started only after pressure in all lines is below the set low limit value.
When center is waiting for pressure discharge completion, there is a phase
dC
in the value
display and time display shows the spent discharge time. Center goes into alarm mode, if the
discharge time is longer than interval time (= lubrication time/2).
3.1.2 Normal mode displays
Buttons
Ï
and
Ð
can be used to browse the normal mode displays which show the lubrication
program set values and to transfer into manual control.
Value display codes change in the following order when
Ï
-button is pressed and vice versa,
when
Ð
-button is pressed.
Display codes
Description
HL
Manual mode
(
H
and
L
ubrication)
CC
Lubrication cycle counter
(
C
ycle
C
ounter)
LC
Lubrication cycle set value
(
L
ubrication
C
ycle)
LP
Maximum pressurization time set value
(
L
ubrication,
P
ressurization time)
Ld
Lubrication delay time, total duration
(
L
ubrication
d
elay)
Code is used only in pressure switch operation
Lo
Low limit pressure set value
(
Lo
w limit pressure)
Code is used only in pressure transmitter operation
Hi
High limit pressure set value
(
Hi
gh limit pressure)
Code is used only in pressure transmitter operation
LF
Center function mode (configuration settings)
(
L
ubrication,
F
unction)
PU
Pressure display unit (configuration settings)
(
P
ressure
U
nit)
Pr
Pressure monitoring unit (configuration settings)
(pressure switch operation/pressure transmitter operation)
(
Pr
essure monitoring unit)
PASS
Entering password
(
PASS
word)
Code shows in time display