SAFEGREASE, SAFEOIL
ST-1100i
110i1CEN.doc
16.04.2003 Rev. 1C
11 (14)
4.3 Entering password
Select code
PASS
at time display.
Enter correct password using
Settings/Pressure
and arrow buttons.
When
Settings/Pressure
button is released, the center goes into Setting mode. The codes
show now decimal points, for example
C.C.
Note
Set value password is
2
.
4.4 Setting mode
Setting mode displays showing the lubrication program set values can be browsed by means of
arrow buttons.
Value display codes change in the following order when
Ï
-button is pressed and vice versa,
when
Ð
-button is pressed.
One can leave Setting mode but browsing to code PASS by means of
Ð
-button.
Display code
Description
C.C.
Lubrication cycle counter
(
C
ycle
C
ounter)
L.C.
Lubrication cycle set value
(
L
ubrication
C
ycle)
L.P.
Maximum pressurization set value
(
L
ubrication,
P
ressurization time)
L.d.
Lubrication delay time coefficient
(
L
ubrication
d
elay)
Code is used only in pressure switch operation
L.o.
Low limit pressure set value
(
Lo
w limit pressure)
Code is used only in pressure transmitter operation
H.i.
High limit pressure set value
(
Hi
gh limit pressure)
Code is used only in pressure transmitter operation
4.4.1 Lubrication cycle counter
Code
C.C
. shows the lubrication cycle counter reading at display.
The counter can be reset by setting the counter value to zero using
Settings/Pressure
and
arrow buttons. The only changeable counter setting is to reset the counter.