SAFEGREASE, SAFEOIL
ST-1100i
110i1CEN.doc
16.04.2003 Rev. 1C
14 (14)
5.2 Connections
All connections are measured for 2.5 mm
2
conductor cross section area.
Input
•
pressure switch, 2 pcs, closing pushbutton
or pressure transmitter, 2 pcs, 4–20 mA / 0–250 bar, 2-wire conductor
•
Lubricant container low limit switch, closing connection
•
Interlocking, lubrication point in operation = switch open
Output
•
Line, 2 pcs, closing pushbutton, connects 24V / 1A max.
•
pump control, closing pushbutton, connects 24V / 5 A max.
•
Alarm, two voltageless exchange switches, loading 50V / 1A max.
Cable channels in the casing
•
5 channels for 7–10 mm cable diameters
•
1 channel for 10-14 mm cable diameters
5.3 Symbols
ST-1100i-xxx
-U
Abbreviation Description
ST: ST
SafeTimer
1100i:
1100i
model, 1-channel control center
xxx: FIN
language, Finnish
ENG
language,
English
SWE
language,
Swedish
GER
language,
German
FRA
language,
French
ITA
language,
Italian
RUS
language,
Russian
SPA
language,
Spanish
POR
language,
Portuguese
NOR
language,
Norwegian
HOL
language,
Dutch
U:
no symbol
power input, 230 V AC ±15% 50/60 Hz
U
power input, 115 V AC ±15% 50/60 Hz
6 SPARE PARTS
See ST-1100i control center spare parts (drawing no. 461544A)