SAFEGREASE, SAFEOIL
ST-1100i
110i1CEN.doc
16.04.2003 Rev. 1C
10 (14)
3.6.4 Electronic system error alarm
The center triggers an electronic system error alarm and goes into alarm mode, if the test
program ran at the start-up detects any errors in the electronic system. The value display shows
phase code
AE
and time display the spent alarm time.
Error code
Description
EP
Program memory check sum error
EE
setting information check sum error
Df
alarm triggered by program execution monitor circuit
Alarm can be acknowledged by pressing the
Alarm acknowledgement
button on the center
cover. If this alarm recurs at the next start-up, please contact the center manufacturer.
4 SETTINGS
4.1 General
Center settings can be divided into two groups:
•
Set
values
•
Configuration
settings
Set values are lubrication system values, for example lubrication cycle and maximum
pressurization time. Set values can be changed in Settings mode.
Configuration settings determine the center functions according to the lubrication system. These
settings are usually factory settings and there should not be any reasons to change them during
operation.
All settings are password-protected.
4.2 Entering settings
1. Select the code for the setting to be changed at the display.
2. Press
Settings/Pressure
button and keep it down.
3. Use arrow buttons to select the desired setting at the display.
4. Release
Settings/Pressure
button and the new setting is stored in the system memory.
Note
If the arrow button is pressed down continuously, settings will change at the
display at accelerating speed.