SETUP MENU

SYSTEM

EVAC v1.24 EN

Operating

To enter the menus, a “secret” key sequence is 
needed.

The following keys need to be pressed in the 

following order: “Left arrow, right arrow, enter, 

enter”.

Then the “CONNECT PIN” access window appears. 
To enter the “CONNECT” menu enter the correct 

PIN.

To get to the setup menu:
•  Press the “secret” key sequence.
•  When the “CONNECT PIN” appears, press the 

right functionkey (the highlighted key in the 
illustration below) for 2 sec. until the “SETUP 
PIN” access window appears.

•  Enter the ADMIN PIN to get to setup menu.

ENTERING MENUS

All parameters in the EVAC system can be setup 

in the entrance station’s “SETUP” menu.

All changes (apart from the real time clock) 

are only made in RAM. Only when exiting the 

setup menu  and answering “YES” to saving the 

settings, the parameters will be saved into the 

unit.

To exit the “SETUP” menu, press and hold the 

left functionkey.

There are two ways to connect to a unit. In 

STANDBY mode it is possible to connect to a unit 

by entering the connect menu. In EVAC mode it 

is always possible to connect to the car, the floor 

stations can only be connected to if an alarm has 

been registered from the unit.

Connection can only be made between the 

entrance station and a floor/car station.

By default the connected floor/car station will 

have the microphone activated and will transmit 

audio onto the audio bus. The entrance station 

receives audio and the speaker is activated. If the 

PTT input is activated on the entrance station, 

the microphone will be activated and the speaker 

inactivated. All other units’ speakers are then 

activated and their microphones deactivated. 

This means that the entrance station has priority 

to speak at all times.

In the EVAC menu, the alarms received are 

displayed with the current alarm floor name 

displayed and the current number of queued 

alarms. The number of queued alarms is updated 

as new alarms are received. 

The alarms are queued in the order they are 

received. To connect to an alarm, move to the 

alarm you want to connect to with the arrow 

up/down, and press “ENTER” to connect. When 

a connection to the alarm has been made, the 

alarm will be removed from the queue.

It is always possible to connect to the car station 

in the EVAC menu by pressing the left function 

key.

In the “CONNECT” menu it is possible to connect 

to the car station and all floor station registered 

in the system. Please note that it is not possible 

to connect nodes without a node ID or nodes 

that have been inactivated in the setup menu on 

the CAN-bus.

SETUP MENU

CONNECT TO A UNIT

EVAC MENU

CONNECT MENU

You can only enter the “SETUP” 

and “CONNECT” menus when in 

STANDBY mode.
The PIN-code is set to  ”0000” 

as the default value.

!

It is possible to change the default 

language (English) to German. 
Select: Setup Menu -> System -> 

Languages -> Deutsch

Summary of Contents for EVAC

Page 1: ...SafeLine EVAC 01 2018 www safeline group com 366 400 110 29 2 5 88 366 383 2 x 4 MANUAL EVAC v1 24 EN Fire communication Evacuation and fire fighting intercom system...

Page 2: ...H Weight 300 g without frontplate IP code IP43 TECHNICAL DATA FLOOR STATION CAR STATION Power 24 VDC In standby 30 mA Active 60 mA Inputs 2 x 24 VDC max 100 mA optically isolated Outputs 2 x 24 VDC m...

Page 3: ...tructure 25 OPERATING Menu tree structure 19 Configuring EVAC 21 CONFIGURATION START UP Overview EVAC entrance station ES 8 Overview EVAC floor station FS 10 Overview EVAC car station CS 12 Overview c...

Page 4: ...liability arising from printing errors mistakes or changes DECLARATION OF CONFORMITY Download The declaration of conformity at our website www safeline group com SAFETY PRECAUTIONS Only trained profes...

Page 5: ...loor Floor 3 Floor 11 Top floor Floor 2 Main entrance CAN1 CAN2 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Yellow Green Red Blue Brown Black Grey Orange Car 1 or Floor 1 3 Floor 4 optional Car 2 1 2 3 4 5 6 7 1 2 3...

Page 6: ...CB Connector board 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Yellow Green Red Blue Brown Black Grey Orange Car Station CS Address selector tens Address selector singles 0 0 Termination ON m ipsum Car Station CS 9 9...

Page 7: ...4 5 6 7 7 6 5 4 3 2 1 Floor Station FS 1 Address selector tens Address selector singles Floor Station FS 2 Address selector tens Address selector singles Floor Station FS 1 Address selector tens Addr...

Page 8: ...ION ES The master unit of the system All commands and logic is handled by the entrance station There can only be one entrance station in an EVAC system The engraved text on the entrance station is ava...

Page 9: ...ARD TERM OFF ON SPK BUS IN 4 IN 3 OUT3 SYSTEM BUS CAN CAN ERR CONTR USB IN 1 IN 2 OUT1 OUT2 SD C ARD TERM OFF ON EVAC v1 24 EN Installation ENTRANCE STATION BACKSIDE Output no 3 Input no 3 Input no 4...

Page 10: ...Installation There can be up to 98 oor stations in one system The engraved text on the oor station is available in english german and swedish OVERVIEW EVAC FLOOR STATION FS Speaker Alarm button with...

Page 11: ...ed by law CANTerminationSwitch ON OFF EVAC v1 24 EN Installation FLOOR STATION RJ45 for Power and Communication CAN termination switch ON OFF Input no 2 Output no 2 USB for firmware update SD card mic...

Page 12: ...ion Note Car station will always have the address 0 0 OVERVIEW EVAC CAR STATION CS Speaker Microphone RJ45 for Power and Communication CAN termination switch ON OFF Input no 2 Output no 2 USB for firm...

Page 13: ...accessories are copyrighted by law 1 2 3 4 5 6 7 7 6 5 4 3 2 1 EVAC v1 24 EN Installation Connection board 1 24 VDC 2 0 V 3 CAN H 4 CAN L 5 GND Shield 6 Audio bus A 7 Audio bus B OVERVIEW CONNECTION B...

Page 14: ...232 connection to SafeLine telephone If used for LMS Lift Monitoring System 3 USB for updating the firmware 4 CAN LED 4 1 CAN 4 2 CAN ERR 5 Termination switch 5 1 CAN2 Car 5 2 CAN1 Shaft 6 Connectors...

Page 15: ...the entrance station The EVAC system is powered by the LMS unit For relay information please see page 26 Car station address 0 0 car 1 or 99 car 2 There can only be one car station in the system Floor...

Page 16: ...d accessories are copyrighted by law 366 400 110 29 2 5 88 366 383 2 x 4 210 90 22 5 25 2 176 17 2 x 6 87 4 56 18 33 7 35 3 226 182 214 54 2 x 9 2 x 5 EVAC v1 24 EN Installation MOUNTING DIMENSIONS Ca...

Page 17: ...law 10 mm EVAC v1 24 EN Installation CUTTING THE CABLE Make sure that the modular plugs RJ45 on the ends of the cable are facing the opposite way see picture The connection cable is used between the c...

Page 18: ...system is working and that the bus is working properly When the entrance station receives a heartbeat from a CAN bus node for the first time it sets the node to the current system mode i e EVAC FIRE...

Page 19: ...24 EN Configuration MENU TREE STRUCTURE EVAC Menu Broadcast soundfile 9 Select sound file Connect to car 9 Connected to node Connect to incoming alarm 9 Connected to node Connect to any node 9 Connect...

Page 20: ...h 9 English Entrance station 9 Backlight 9 Volume 9 Inputs 9 Input function 9 Outputs 9 Output function 9 Hardware version 9 Software version Car 9 Volume 9 Hardware version 9 Software version 9 Mic L...

Page 21: ...in the names for the Soundfiles Sound file triggers All floor stations have the possibility to play sound files This is done by either manually triggering broadcast sound file in the EVAC menu the pl...

Page 22: ...the car station Please note The EVAC system can be configured to operate the lift in any way You can configure an input to trigger the EVAC mode in the setup menu The system will be in EVAC mode as l...

Page 23: ...n is automatically a fire unit The floor stations that should be fire units need to be configured in the setup menu When in FIRE mode the car station is always connected to the audio bus and all sound...

Page 24: ...connected floor car station will have the microphone activated and will transmit audio onto the audio bus The entrance station receives audio and the speaker is activated If the PTT input is activated...

Page 25: ...ween tests Start self test Activate the self test Read config from SD Reads configuraton from the SD card Factory reset Reset all parameters not RTC to factory default The reset is only in RAM so to s...

Page 26: ...aker volume for the node SoundFiles When in the sound files Press Up key Down key to select another sound file Mode Mode for the sound files Off On Repeat Repeat Delay time s between repeats Indicate...

Page 27: ...ed LOG on the entrance station s SD card The log file is a txt file and can be opened in any text editor Each log entry consists of ENTRY Serial number starting on 1 TIME Time stamp parsed from the re...

Page 28: ...e eu SafeLine Norway Solbr veien 49 1383 Asker Norway Tel 47 94 14 14 49 post safeline no SafeLine Headquarters Antennv gen 10 135 48 Tyres Sweden Tel 46 0 8 447 79 32 info safeline se Support 46 0 8...

Reviews: