Phoenix G2 IDU User Manual INSTALLATION
SAF Tehnika JSC
41
3
Attach the mounting plate to IDUs and fix it to
IDUs using the same existing screws
4
Final view of back panel of interconnected IDUs
Install both devices in the rack using attached rack mount brackets.
Figure 2.2
Dual device installation
-
Ground Phoenix G2 IDU by interconnecting it’s grounding screw with the grounding point
of the rack
-
In case if the Phoenix G2 IDU will be used in
1+0 Ch1
mode, connect ODU to the IDU’s IF
port
ODU A
with coaxial cable before turning on the power
-
In case if the Phoenix G2 IDU will be used in
1+0 Ch2
mode, connect ODU to the IDU’s IF
port
ODU B
with coaxial cable before turning on the power
-
In case if the Phoenix G2 IDU will be used in modes
1+1 Dual
,
2+0
or
1+1
, connect ODUs to
the IDU’s IF ports
ODU A
and
ODU B
with coaxial cables before turning on the power
In case of IDU tests in the lab without ODU, the IDU can be powered on without ODU
connected, it will not damage the unit
Attaching Phoenix G2 ODU to antenna
SP/HP ODU
Tools required
: SAF tightening tool
In order to attach SP/HP ODU to SAF adopted antenna use two guidance pins for fixing
polarization and 4 side lockings for attachment. Lockings should be tightened in diagonal
sequence.