Phoenix G2 IDU User Manual OVERVIEW
SAF Tehnika JSC
13
Figure 1.11
PhoeniX G2 1+1 SD configuration
PhoeniX G2 1+1 Full protection configuration:
1+1 HSB, FD and SD full protection is provided. SD supports only fixed hot-
swap role – primary or secondary
This protection type protects the link also against IDU, power supply and
interface failures
In case of protection, when the Primary link fails, the secondary re-configures
itself to the Primary role
Figure 1.12
PhoeniX G2 1+1 full protection configuration
2.5 Gbps SFP modules must be used for both IDU FO interconnection. In Design Type 511
both SFP ports work in “Forced 2G5” mode.
PhoeniX G2 2+0/2+0 XPIC configurations:
2+0 configuration is used to aggregate payload traffic (capacity doubling). In
this case 2 frequency channels are required
2+0 XPIC configuration is used to aggregate payload traffic using 1 frequency
channel in both polarizations Vertical and Horizontal simultaneously