Phoenix G2 IDU User Manual
WEB GUI
SAF Tehnika JSC
56
information from the device and renders it on
the screen.
The colour of configuration value entered in a setting box indicates the status of the following
value:
black
– unmodified value
blue
– modified but non-applied value
red
– entered value does not match the allowed range
purple
– the actual configuration does not match the required modem settings.
Setting input boxes may change its border colour to red if the entered value is not applicable,
for example, invalid IP address or a character in an integer-type field. In such event, the
button is hidden until the problem is fixed.
Configuration of basic system parameters
In order to establish the link, following main configuration steps should be performed:
1)
Step 1
– in web GUI navigate to “
” and specify
Design Type
,
Duplex mode
and
Functional Mode
. With those settings user defines the basic
configuration of the equipment:
a)
1+0 single channel configuration,
b)
1+0 dual channel configuration,
c)
1+1 (HSB, FD, SD, XPIC) standard redundancy configuration,
d)
1+1 (HSB, FD, SD) full redundancy configuration,
e)
2+0 FD aggregation configuration,
f)
2+0 XPIC aggregation configuration
g)
Bidirectional transmission
h)
Unidirectional transmission
Figure 3.7
Design and modes configuration
2)
Step 2
– in web GUI “
” configure
IP address/subnet mask
and
Gateway IP
address of the IDU.