Phoenix G2 IDU User Manual INSTALLATION
SAF Tehnika JSC
46
3
Use air level to verify that VHP ODU is properly
levelled. Tighten all four fixation clamps properly.
4
Final view of assembled VHP ODU 1+0 setup.
5
Final view of assembled SP/HP ODU with SAF2
adapter in Horizontal polarization
6
Final view of assembled SP/HP ODU with SAF2
adapter in Vertical polarization
Acceptable angle of polarization tolerance of SP/HP ODU is up to 30º
If any further assistance is required please contact [email protected]
Cable requirements
IDU-ODU cable:
IDU–ODU cable is a 50 Ω coaxial cable intended to interconnect the Indoor Unit with the
Outdoor Unit. Any type of 50 Ω cable of good quality can be used; the cable should be equipped
with N–type male connectors on each end. There are two N–type male connectors included in
each radio unit delivery that fit RG–213 cables or other cables with a surface diameter of 10
mm. As the attenuation of the cable is essential particularly at 350 MHz frequency, its usage is
restricted, - the attenuation of the signal should not exceed 15 dB at 350 MHz.