CHYBA! NA POUŽITIE ŠTÝLU TITRE 1 NA TEXT, KTORÝ SA MÁ ZOBRAZIŤ NA TOMTO MIESTE, POUŽITE KARTU DOMOV.
CHYBA! NA POUŽITIE ŠTÝLU TITRE 2 NA TEXT, KTORÝ SA MÁ ZOBRAZIŤ NA TOMTO MIESTE, POUŽITE KARTU DOMOV.
14
NERTABLOC TH
400
PW
Il y a lieu d'envisager la liaison électrique de tous les
composants métalliques de l'installation de soudage et
des composants voisins. Toutefois, des éléments
métalliques reliés à la pièce accroissent le risque pour
l'opérateur de chocs électriques s'il touche à la fois ces
éléments métalliques et l'électrode. Il convient d'isoler
l'opérateur de tels éléments métalliques.
Bonding of all metallic components in the welding
installation an adjacent to it should be considered.
However, metallic components bonded to the work piece
will increase the risk that the operator could receive a
shock by touching these metallic components and the
electrode at the same time. The operator should be
insulated from all such bonded metallic components.
A2.5
Mise à la terre de la pièce à souder
A2.5
Earthing of the workpiece
Quand la pièce n'est pas reliée à la terre pour la sécurité
électrique ou en raison de ses dimensions et de son
emplacement, cas des coques de navires ou des
charpentes métalliques de bâtiments, une connexion
raccordant la pièce à la terre pourra, dans certains cas
et non systématiquement, réduire les émissions. Il
faudra éviter la mise à la terre des pièces qui pourrait
accroître les risques pour l'opérateur ou endommager
d'aut
res équipements électriques. Si nécessaire, il
convient que le raccordement de la pièce à la terre soit
fait directement mais dans certains pays n'autorisant pas
cette connexion directe, il convient que la connexion soit
faite avec un condensateur appropri
é choisi en fonction
des réglementations nationales.
Where the workpiece is not bonded to earth for electrical
safety, nor connected to earth because of its size and
position, e.g. ships hull or building steelwork, a
connection bonding the workpiece to earth may reduce
emissions in some, but not all instances. Care should be
taken to prevent the earthing of the workpiece increasing
the risk of inury to users, or damage to other electrical
equipment. Where necessary, the connection of the
workpiece to earth should be made by a direct
connection to the workpiece, but in some countries
where direct connection is not permitted, the bonding
should be achieved by suitable capacitance, selected
according to National regulations.
A2.6
Blindage et protection
A2.6
Screening and shielding
Le blindage et la protection sélectifs d'autres câbles et
matériels dans la zone environnante peut limiter les
problèmes d'interférences. Le blindage de toute
l'installation de soudage peut être envisagé pour des
applications s
péciales.
Selective screening and shielding of other cables and
equipment in the surrounding area may alleviate
problems of interference. Screening of the entire welding
installation may be considered for special applications.
Summary of Contents for NERTABLOC TH 400 PW
Page 4: ......
Page 7: ...NERTABLOC TH 400 PW 3 ...