INTEGRA/-S/-G/-GS User Manual WEB GUI
SAF Tehnika JSC
87
6)
By pressing
„Execute configuration”
,
changes made to the corresponding section
apply only to the local side Integra/Integra-S/Integra-G/Integra-GS.
CLI commands (
Chapter 4: COMMAND LINE INTERFACE
log group info
Use to show sensor group configuration.
log group create
<name>
<description>
Use to create a new group.
log group mgmt
<name>
add
destination
{event|perf|snmp|syslog}
Use to add a destination for a group.
log group mgmt
<name>
add
sensor
<sensor>
Use to add a sensor to a group.
log group mgmt
<name>
config
{enable|disable}
Use to enable or disable a group.
log group mgmt
<name>
delete
Use to delete a group.
log group mgmt
<name>
remove
destination {
event|perf|snmp|syslog}
Use to remove a destination from a group.
log group mgmt
<name>
remove
sensor
<sensor>
Use to remove a sensor from a group.
log sensor info
Use to show current sensor status.
log sensor list
Use to list all available sensors.
log default
{all|group|sensors
[<sensor>]}
Use to set group, individual sensor, or all sensor
configuration to default.
Performance
→
Alarm
→
Alarm threshold configuration
The page provides a summary of the
parameters’ alarm thresholds. All thresholds are
predefined and some change dynamically according to the system configuration. Thresholds
can be modified if required.
Alarm activates when current value exceeds (low-delta) or (high+delta) values. Alarm
deactivates when current value exceeds (low+delta) or (high-delta) values.
Summary of Contents for Integra
Page 1: ...SAF Tehnika JSC 1 User manual Integra Integra S Integra G Integra GS VER 2 37 FW 3 20 19...
Page 63: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 63 Status mode Press button...
Page 88: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 88 Status mode Press button...
Page 94: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 94 Status mode...