INTEGRA/-S/-G/-GS User Manual OVERVIEW
SAF Tehnika JSC
7
The frequency range of subband B low side Integra 18 GHz FODU:
The minimum available bandwidth is 1.75 MHz
*
*
Inquire SAF representative for more information
Microwave Radiation
In April 1998, ICNIRP (International Commission on Non-Ionizing Radiation Protection)
published its ´Guidelines for limiting exposure to time-varying electric, magnetic, and
electromagnetic fields (up to 300GHz)´. As shown in Table 2.2-1, the guidelines (Tables 6 and
7) specify the ´Reference levels on power density for occupational exposure and general
public exposure to time-varying electric and magnetic fields (unperturbed rms values)´
between 2 and 300 GHz.
ICNIRP Reference levels
Frequency
range
Exposure
characteristics
Equivalent plane
wave power density
Seq (W/m2)
Average time period
(min)
5.8 GHz
occupational 458 cm (181 in)
50
68/f
1.05
(f in GHz)
general public 1025 cm (404 in)
10
68/f
1.05
(f in GHz)
24 GHz
occupational 41 cm (16 in)
50
68/f
1.05
(f in GHz)
general public 91 cm (36 in)
10
68/f
1.05
(f in GHz)
Note:
For pulsed signals, it is suggested that the peak equivalent plane wave power density, as averaged over the
pulse width, does not exceed 1000 times the Seq exposure levels given in the table.
Note:
Within the frequency range the 10
–
300 GHz the basic restrictions are identical to the reference levels.
Remarks on the definition of basic restrictions:
1. Power densities are to be averaged over any 20 cm
2
of exposed area and any 68/f1.05 minute period (where f is in
GHz) to compensate for progressively shorter penetration depth as the frequency increases.
Summary of Contents for Integra
Page 1: ...SAF Tehnika JSC 1 User manual Integra Integra S Integra G Integra GS VER 2 37 FW 3 20 19...
Page 63: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 63 Status mode Press button...
Page 88: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 88 Status mode Press button...
Page 94: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 94 Status mode...