INTELIA 04 OPERATING LOGIC
Saeco International Group
Rev. 02 / September 2012
Page / 08
4.8. Water level detection (water tank)
“Water low” message (water reserve)
Function:
The water level is monitored by a capacitative sensor, located one
third of the way up the water tank wall.
If the electronics assembly detects, by means of the sensor,
that the amount of water in the tank has dropped below the
above mentioned level, a water reserve remains available for
the dispensing process underway (this will cover 200
fl
ow meter
pulses).
The product dispensing process will then come to an end.
If a dispensing cycle ends after the sensor has been triggered (in
the reserve) then the display “Water low” continues to be displayed
during the following dispensing cycle.
200 puls.
Sensor
Water tank
07
“Descaling” – message with water
fi
lter
inserted
(appliances with display only)
The water hardness is set on the basis of the
regional water hardness analysis
(1, 2, 3, 4).
Filter off:
If the function is turned
off
the electronics
assembly monitors the
fl
ow meter pulses,
recording
one pulse each turn
.
Filter on:
If the function is turned
on
the electronics
assembly monitors the
fl
ow meter pulses,
recording
one pulse every two turns
.
“Change water
fi
lter” message
The electronics assembly uses the
fl
ow meter
impulses to keep track of the amount of water
which has
fl
owed through; after the speci
fi
ed
amount (set in accordance with the water
hardness level), the “Replace
fi
lter” message
appears.
4.9.
Descaling
request
360°
1 rev
Number of pulses
Filter
on
Filter
off
Flow meter pulses
Summary of Contents for Intelia
Page 3: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 1 INTRODUCTION...
Page 9: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 13: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 3 USER INSTRUCTIONS...
Page 24: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 4 OPERATING LOGIC...
Page 33: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 5 TROUBLESHOOTING...
Page 56: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 6 STANDARD CHECKS...
Page 59: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 7 DISASSEMBLY...
Page 71: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 8 NOTES...
Page 72: ...INTELIA 08 NOTES Saeco International Group Rev 02 September 2012 Page 01 01...
Page 73: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 9 WATER CIRCUIT DIAGRAM...
Page 76: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 10 ELECTRICAL DIAGRAM...