INTELIA 05 TROUBLESHOOTING
Saeco International Group
Rev. 02 / September 2012
Page / 22
ERROR
ERROR
CODES
CODES
DESCRIPTION
DESCRIPTION
01
01
The coffee grinder is blocked (grinder blades jammed or sensor not
reading properly)
03
03
The brewing unit is blocked in work position (microswitch not released
in up position after 3", torque error trying to move down, descent time
out exceeded)
04
04
The brewing unit is blocked in home position (microswitch not released
in down position after 3", torque error trying to move up, ascent time
out exceeded)
05
05
Water circuit /
fl
ow meter problems (water circuit blocked or no
fl
ow
meter signal)
10
10
Boiler temperature sensor short circuited
11
11
Boiler temperature sensor open circuit
14
14
The boiler temperature has exceeded the maximum allowed value
(165°c)
15
15
The boiler temperature has not increased by x°C in y sec (boiler power
supply disconnected, incorrect boiler
fi
tted must be a 1300W boiler, par-
tial power supply to boiler, cut out thermostat tripped)
19
19
Mains voltage trouble
5.2. Error
codes
22
Summary of Contents for Intelia
Page 3: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 1 INTRODUCTION...
Page 9: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 13: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 3 USER INSTRUCTIONS...
Page 24: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 4 OPERATING LOGIC...
Page 33: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 5 TROUBLESHOOTING...
Page 56: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 6 STANDARD CHECKS...
Page 59: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 7 DISASSEMBLY...
Page 71: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 8 NOTES...
Page 72: ...INTELIA 08 NOTES Saeco International Group Rev 02 September 2012 Page 01 01...
Page 73: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 9 WATER CIRCUIT DIAGRAM...
Page 76: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 10 ELECTRICAL DIAGRAM...